Electrical Connection; Water Connection, Regardless Of Any Options; Ventilation - Wexiodisk WD-11 touch Installation And User Manual

Tunnel dishwasher
Hide thumbs Also See for WD-11 touch:
Table of Contents

Advertisement

Installation instructions

3.5.1 Electrical connection

3.5.2 Water connection, regardless of any options

3.5.3 Ventilation

Information about electrical connections is available on the machine's wiring dia-
gram which is provided on delivery. Store these in the special plastic document
wallet.
The machine is designed for quick electrical installation.
The machine must be connected to a lockable power switch. This should
be placed on a wall, well-protected from water and from the steam which
escapes when the machine is opened.
Connect the cable at (1), or alternatively the machine may have an electri-
cal connection from the floor (6). Protect the incoming cable with, e.g. Pipe
for connection cable, WD212.4102 (option).
Check the direction of rotation of the pump motors during operation when
the tanks are full of water. The direction of rotation must conform without
exception to the direction of the arrow on the pump. Stop the dishwasher
immediately if the direction of rotation is incorrect and change two of the
incoming phases.
After completing the installation, switch on the power switch and all circuit break-
ers.
A shut-off cock must be installed on the incoming pipe.
It is important that the water supply has sufficient pressure to ensure the
correct flow of water to the machine. The required water flow and pressure
can be found in the TECHNICAL SPECIFICATIONS. If the water pressure
is too low, a booster pump must be fitted.
The water pipe is connected at (2), or alternatively at (7). If the machine is con-
nected with a hose, this should be steel braided and have an internal diameter of
at least 12 mm.
The water connection on the machine is fitted with a filter, non-return valve and
vacuum valve.
As the machine is fitted with a "break tank", the connection is fitted with a filter and
non-return valve.
The machine's heat load for the room is stipulated in TECHNICAL SPECIFICA-
TIONS.
Connection to the ventilation duct is done at the outfeed (5) and the infeed (12).
If a hood is fitted over the machine, it must cover the drying rack after the ma-
chine.
WD-11
touch
14
Rev. 00 (202310)