Reading The Tag Configuration Data - Siemens SIMATIC RF310M Operating Instructions Manual

Simatic ident
Hide thumbs Also See for SIMATIC RF310M:
Table of Contents

Advertisement

RF-MANAGER RF310M software
9.3 Application mode "Mobile"
Only complete rows with 4 bytes each are write-protected.
If, for example, you only select the 2nd byte in the data editor using the "Address" FF05 and
"Length" 1, only this byte is transferred to the EEPROM area on the tag, but the address
range FF04...FF07 is protected.
A write operation is carried out internally at block address FF84.
The OTP area refers to the 5 block addresses FF80, FF84, FF88, FF8C and FF90. A write
command to this block address with a valid length (4, 8, 12, 16, 20 depending on the block
address) protects the written data from subsequent overwriting.
Note
If the OTP area is used, it must be ensured that the blocks are used without gaps, starting
with block 0.
Examples:
3 blocks (with write command), blocks 0, 1, 2 (FF80, length = 12): valid
2 blocks (consecutive), block 0 (FF80, length =4), block 1 (FF84, length = 4): valid
2 blocks (consecutive), block 0 (FF80, length =4), block 2 (FF88, length = 4): invalid
1 block, block 4 (FF90, length = 4): invalid
9.3.5.5

Reading the tag configuration data

You can read the configuration data of a tag by selecting the memory area "CONFIG" in the
editor and subsequently carrying out a read operation. The memory area "CONFIG" only
exists with RF300 tags.
Byte address
0xFF1f
0xFF1e
0xFF1d
0xFF1c
0xFF1b
0xFF1a
0xFF19
0xFF18
0xFF17
0xFF16
0xFF15
0xFF14
78
EEPROM
Bank switch (bits 1 and 0)
MDS delay (bits 7:5); LFD (bit 4)
Reserved
Limit value A for LFD quotients
Limit value B for LFD quotients
Reserved
Memory configuration, INIT (bits
7...1)
Range for lock bits
Tag ID, byte 3
Tag ID, byte 2
Tag ID, byte 1
Tag ID, byte 0
Functional description
Memory bank
MDS delay/LFD bit
LFD (A)
LFD (B)
Memory configuration/Init bit
Lock bits
Tag ID (b24-b31)
Tag ID (b16-b23)
Tag ID (b8-b15)
Tag ID (b0-b7)
Operating Instructions, 10/2013, J31069-D0191-U001-A6-7618
SIMATIC RF310M Mobile Reader