Chapter 9 Function Parameter Table - Veichi AC300 Series Technical Manual

Hide thumbs Also See for AC300 Series:
Table of Contents

Advertisement

AC300 Series Vector Control Inverter Manual
Predetermined area:
Expansion port EX-A
LED digits ten digits: address lower 8 digits
F13.19
monitoring frame
00~63
address group 1
LED hundred thousand digits: address high 8 digits
00~07
Expansion port EX-A
F13.20
monitoring frame
Setting range: Same as above
address group 2
Expansion port EX-A
F13.21
monitoring frame
Setting range: Same as above
address group 3
Expansion port EX-A
F13.22
monitoring frame
Setting range: Same as above
address group
LED "0" and "00"digits: up and down keys to modify the serial number 00 ~ 99
LED "000" and "0000"digits: up and down keys modify group number 00~15,
For example, set F13.19 to 0001 for C00.01 then do it by that analogy.
Predetermined area:
Expansion port EX-B
LED digits ten digits: address lower 8 digits
F13.23
monitoring frame
00~63
address group 1
LED hundred thousand digits: address high 8 digits
00~07
Expansion port EX-B
F13.24
monitoring frame
Setting range: Same as above
address group 2
Expansion port EX-B
F13.25
monitoring frame
Setting range: Same as above
address group 3
Expansion port EX-B
F13.26
monitoring frame
Setting range: Same as above
address group 4
LED "0" and "00"digits: up and down keys to modify the serial number 00 ~ 99
LED "000" and "0000"digits: up and down keys modify group number 00~15,
For example, set F13.23 to 0001 for C00.01 then do it by that analogy.
Function Parameter Specifications
Factory
default: 0001
Factory
default: 0002
Factory
default: 0007
Factory
default: 0011
Factory default:
0001
Factory default:
0002
Factory default:
0007
Factory default:
0011
148
AC300 Series Vector Control Inverter Manual

Chapter 9 Function Parameter Table

Function parameter profile:
"●": Parameter can be changed in the running state.
"〇": Parameter can't be changed in the running state.
"×": Parameter can be read only.
"–": Factory setting parameter, only factory can set.
"※": Parameter is related to the model.
Basic parameters:
Function
NO.
Range of settings and definition
description
Asynchronous motor control mode:
0: V/F control
3: High-performance VC without PG
4: High-performance VC with PG
Synchronous motor control mode:
F00.00
Motor control mode
6: High-performance VC without PG
7: VC with PG
Other control:
8:Voltage frequency separation output
1/2/5: Reserved
F00.01
Reserved
0: Keyboard
2: RS485 communication
Run command
control
F00.02
control
channel
1: Terminal
3: Reserved
control
0: Keyboard number given
1: Reserved
2: Voltage/Current analog AI1 given
Frequency given
F00.03
3: Voltage/Current analog AI2 given
source channel A
4: Reserved
5: Terminal pulse PUL given
6: RS485 communication given
7: Terminal UP/DW control
8: PID control given
Frequency given
F00.04
9: Program control (PLC) given
source channel B
10: Optional card
11: Multi-steps speed given
0: Max. output frequency as reference source
Frequency channel
F00.05
1: Set frequency of channel A as reference
B reference source
source
Function Parameter Table
Factory
Feat
Addres
default
ure
s
0
0x000
0x001
0
0x002
0
0x003
1
0x004
0
0x005
149