AC300 Series Vector Control Inverter Manual
LED"00"digit: Time unit
0: second
1: minute
2: hour
LED"000"digit: Power down save mode
0: no save
1: save
This parameter is defined as when the selection process is running, the inverter power whether to store the current
state of the running program (running stages, the remaining time of this stage, deceleration and running direction , etc.).
If you choose power down storage, the "000"digit of [F12.15] defines the way power is restored of the next running. To
ensure sustainable state of inverter after power recovery, the parameter should be set as "1".
LED"0000"digit: Start-up mode
0: Restart from the 1st step
1: Restart from the step where stop
2: Restart from the time when stop
Set restart mode while stop for some reasons (stop, fault, power off and so on).
Choosing 0: Restart from the 1st step
Choosing 1: Restart from the step when stop
Choosing 2: Continue from the time when stop
Note: Output frequency is limited by upper/lowest limitation. While frequency is lower then lowest limitation, it
runs as [F0.13] lowest limitation mode.
Function Parameter Specifications
140
AC300 Series Vector Control Inverter Manual
F12.16
PLC 1st step running time
Setting range: 0.0-6500.0(s/m/h)
F12.17
PLC 2nd step running time
Setting range: 0.0-6500.0(s/m/h)
F12.18
PLC 3rd step running time
Setting range: 0.0-6500.0(s/m/h)
F12.19
PLC 4th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.20
PLC 5th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.21
PLC 6th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.22
PLC 7th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.23
PLC 8th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.24
PLC 9th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.25
PLC 10th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.26
PLC 11th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.27
PLC 12th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.28
PLC 13th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.29
PLC 14th step running time
Setting range: 0.0-6500.0(s/m/h)
F12.30
PLC 15th step running time
Setting range: 0.0-6500.0(s/m/h)
Set running time of every 15 steps. Time unit is decided by [F12.15] LED "00" digit setting.
F12.31
PLC 1st step direction and ADD/DEC time
F12.32
PLC 2nd step direction and ADD/DEC time
F12.33
PLC 3rd step direction and ADD/DEC time
F12.34
PLC 4th step direction and ADD/DEC time
F12.35
PLC 5th step direction and ADD/DEC time
F12.36
PLC 6th step direction and ADD/DEC time
F12.37
PLC 7th step direction and ADD/DEC time
F12.38
PLC 8th step direction and ADD/DEC time
F12.39
PLC 9th step direction and ADD/DEC time
F12.40
PLC 10th step direction and ADD/DEC time
F12.41
PLC 11th step direction and ADD/DEC time
F12.42
PLC 12th step direction and ADD/DEC time
F12.43
PLC 13th step direction and ADD/DEC time
F12.44
PLC 14th step direction and ADD/DEC time
F12.45
PLC 15th step direction and ADD/DEC time
Set running direction and ACC/DEC time of every 15 step while program running.
LED "0" digit: this step run direction
0: FWD
Function Parameter Specifications
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Setting range:
Factory set: 0000
0000-0031
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
141

Advertisement

Table of Contents
loading

Table of Contents