AC300 Series Vector Control Inverter Manual
LED"0" digit: Feedback feature
selection
0: Positive feature
feature
F11.07
PID control selection
LED"00"/"000" digit: Reserved
LED"0000" digit: Differential
adjustment properties
0: Differential bias
1: Differential of feedback
F11.08
PID preset output
0.0~100.0%
PID preset output
F11.09
0.0~6500.0s
running time
PID control deviation
F11.10
0.0~100.0%
F11.11
Proportional gain P1
0.000~8.000
F11.12
Integral time I1
0.0~600.0s
F11.13
Differential time D1
0.000~6.000s
F11.14
Proportional gain P2
0.000~8.000
F11.15
Integral time I2
0.0~600.0s
F11.16
Differential gain D2
0.000~6.000s
0: No switch
PID Parameter
F11.17
1: Use DI terminal to switch
switching condition
2: Switch according to deviation
Low value of
F11.18
0.0~100.0%
switching deviation
High value of
F11.19
0.0~100.0%
switching deviation
F11.20
Reserved
F11.21
Differential limit
0.0~100.0%
F11.22
PID output upper limit
0.0~100.0%
F11.23
PID output lower limit
-100.0~F11.19
F11.24
PID output filter time
0.000~6.000s
Feedback wire break
F11.25
0.0~120.0s
detection time
0: Go on PID operation without alarm
1: Stop and alarm malfunction
Feedback wire break
2: continue to PID operation and
F11.26
action selection
output alarm signal
3: Run at the current frequency and
output alarm signal
Wire break alarm
F11.27
0.0~100.0%
F11.28
Wire break alarm
0.0~100.0%
Close-loop suspend
F11.29
0.0~100.0%
detection threshold
Close-loop suspend
F11.30
0.0~600.0s
detection time
Function Parameter Table
1:Negative
0100
0xB07
100.0%
0xB08
0.0s
0xB09
0.0%
0xB0A
0.100
0xB0B
1.0s
0xB0C
0.000s
0xB0D
0.100
0xB0E
1.0s
0xB0F
0.000s
0xB10
0
0xB11
20.0%
0xB12
80.0%
0xB13
0xB14
5.0%
0xB15
100.0%
0xB16
0.0%
0xB17
0.000s
0xB18
1.0s
0xB19
0
0xB1A
100.0%
0xB1B
0.0%
0xB1C
0.0%
0xB1D
1.0s
0xB1E
170
AC300 Series Vector Control Inverter Manual
Multi-Speed and PLC Function Parameter Group
NO.
Function description
Range of setting and definition
F12.00
PLC Speed 1
0.00~Max frequency
F12.01
PLC Speed 2
0.00~Max frequency
F12.02
PLC Speed 3
0.00~Max frequency
F12.03
PLC Speed 4
0.00~Max frequency
F12.04
PLC Speed 5
0.00~Max frequency
F12.05
PLC Speed 6
0.00~Max frequency
F12.06
PLC Speed 7
0.00~Max frequency
F12.23
PLC Speed 8
0.00~Max frequency
F12.08
PLC Speed 9
0.00~Max frequency
F12.09
PLC Speed 10
0.00~Max frequency
F12.10
PLC Speed 11
0.00~Max frequency
F12.11
PLC Speed 12
0.00~Max frequency
F12.12
PLC Speed 13
0.00~Max frequency
F12.13
PLC Speed 14
0.00~Max frequency
F12.14
PLC Speed 15
0.00~Max frequency
LED"0" digit: cycle mode
0: Stop after single cycle
1: Continuous cycles
2: Keep final value after single cycle
LED"00" digit: Time unit
0: second
2:hour
PLC Running mode
F12.15
LED"000" digit: Power down
selection
memory
0: Not save
LED"0000" digit: Start mode
0: Restart from the 1st stage
1: Restart from the stop stage
2: Continue running from the time
when stop
PLC 1st step running
F12.16
0.0~6500.0(s/m/h)
F12.17
PLC 2nd step running
0.0~6500.0(s/m/h)
F12.18
PLC 3rd step running
0.0~6500.0(s/m/h)
F12.19
PLC 4thstep running time
0.0~6500.0(s/m/h)
F12.20
PLC 5th step running
0.0~6500.0(s/m/h)
F12.21
PLC 6th step running
0.0~6500.0(s/m/h)
PLC 7th step running
F12.22
0.0~6500.0(s/m/h)
F12.23
PLC 8th step running
0.0~6500.0(s/m/h)
PLC 9th step running
F12.24
0.0~6500.0(s/m/h)
F12.25
PLC 10th step running
0.0~6500.0(s/m/h)
F12.26
PLC 11th step running
0.0~6500.0(s/m/h)
Function Parameter Table
Factory
Feature
Address
default
10.00Hz
0xC00
20.00Hz
0xC01
30.00Hz
0xC02
40.00Hz
0xC03
50.00Hz
0xC04
40.00Hz
0xC05
30.00Hz
0xC06
20.00Hz
0xC07
10.00Hz
0xC08
20.00Hz
0xC09
30.00Hz
0xC0A
40.00Hz
0xC0B
50.00Hz
0xC0C
40.00Hz
0xC0D
30.00Hz
0xC0E
1: minute
0000
0xC0F
1: save
10.0
0xC10
10.0
0xC11
10.0
0xC12
10.0
0xC13
10.0
0xC14
10.0
0xC15
10.0
0xC16
10.0
0xC17
10.0
0xC18
10.0
0xC19
10.0
0xC1A
171