AC300 Series Vector Control Inverter Manual
1: write operation without response
F13.09

Modbus main machine sending selections

Set the data that inverter sent the slave machines when inverter is main machine.All slaves will receive the command
from the host when the main machine sends broadcast commands.
The host can send four polling data, corresponding to the settings of LED "0" digit, "00" digit,"000" digit and "0000"
digit. No data is transmitted when invalid.
LED "0" digit: 1st group of frame selection
0: Invalid
1: Main machine run command
2: Main machine given frequency
3: Main machine output frequency
4: Main machine upper limit frequency
5: Main machine given torque
6: Main machine output torque
7: Reserved
8: Reserved
9: Main machine given PID
A: Main machine feedback PID
B: Reserved
C: active current component
LED "00" digit: 2nd group of frame selection
as above
LED "000" digit: 3rd group of frame selection
as above
LED "0000" digit: 4th group of frame selection
as above
Host broadcast data
Corresponding address and application accepted by Slaver
1: running command given
0x3001, Can be used as the data of running command given source
0x01:FWD run
0x02:REV run
0x03:FWD jog
0x04:REV jog
0x05:Stop command (Slave machine stops according stop mode)
2: Main machine given frequency
0x3000, can be used as communication given frequency
3: Main machine output frequency
0x3000, can be used as communication given frequency
4: Main machine upper limit frequency
0x3004, can be used as communication given frequency upper limit
5: Main machine given torque
0x3005, can be used as communication given torque
6: Main machine output torque
0x3005, can be used as communication given torque
7: Reserved
8: Reserved
9: Main machine given PID
0x3008, can be used as PID communication given
Function Parameter Specifications
Setting range: 0000-BBBB
Factory set: 0031
146
AC300 Series Vector Control Inverter Manual
A: Main machine feedback PID
0x3009, can be used as PID communication given
F13.10

RS485 communication port configuration

RS485 communication port configuration
0: Modbus communication: general Modbus method
1: Serial port monitoring: monitoring inverter running state by upper machine.
2: Reserved
LED "0" digit t: EX-A port disconnection action mode
Expansion port
LED "00" digit: EX-B port disconnection action mode
communication
F13.16
0: no detection
disconnection
1: alarm and free parking
processing
2: Warning and continue to run
LED "0" digit: Set EX-A port disconnection action mode
0: no detection
1: alarm and free parking
2: Warning and continue to run
LED "00" digit: set EX-B port disconnection action mode
0: no detection
1: alarm and free parking
2: Warning and continue to run
F13.17

Expansion port EX-A parameter update

F13.18

Expansion port EX-B parameter update

LED "0" digit: EX-A port disconnection action mode
0: no detection
1: alarm and free parking
2: Warning and continue to run
LED "00" digit: EX-B port disconnection action mode
0: no detection
1: alarm and free parking
2: Warning and continue to run
Function Parameter Specifications
Setting range: 0-2
Factory default: 0
Factory default: 0
Setting range: 0~2
Factory default: 0
Setting range: 0~2
Factory default: 0
147