Veichi AC300 Series Technical Manual page 82

Hide thumbs Also See for AC300 Series:
Table of Contents

Advertisement

AC300 Series Vector Control Inverter Manual
LED "0" digit: C00.00-C00.39
0: Normal
1: Debugging
Monitor display
F04.23
LED "00" digit: C00.40-C00.69
selection
0: No display 1: Normal display
Rotate speed display
F04.24
0.0~500.0%
coefficient
F04.25
Power display
0.0~500.0%
LED "0" digit: E.EEP fault (EEPROM
storage fault)
F04.26
Alarm selection 1
0: Alarm and free stop
1: Alarm and continue operation
F04.27
Reserved
0:After power on the fan runs
1: Stop associated with temperature,
F04.28
Fan control
running is rotary
2: Running associated with temperature,
stop while the fan stops
F04.29
Energy braking enable
0:Off
Energy braking
F04.30
115.0%~140.0%
operation voltage
Energy braking
F04.31
0.0~100.0%
F04.32
PWM carrier
0.7~16.0kHz
LED "0" digit: carrier associated with
temperature
0: Temperature independent
1: Temperature dependent
LED "00" digit : carrier associated
with output frequency
0:not associated
F04.33
PWM control mode
LED "000" digit: random PWM valid
0: Prohibited
LED "0000" digit: PWM modulation
mode
0: Only use three-phase modulation
1: Two-phase and three-phase
modulation automatically switched
Motor Parameters
NO.
Function description
Range of settings and definition
0: Asynchronous motors (AM)
F05.00
Motor mode
1: Permanent magnet synchronous
F05.01
Number of motor poles
2~98
F05.02
Motor rated power
0.1~1000.0kW
Function Parameter Table
0000
0x417
0000
0x418
100.0%
0x419
100.0%
0x41A
0000
0x41B
1
0x41C
1:On
0
0x41D
125.0%
0x41E
10.0%
0x41F
Model
0x420
1: associated
1111
0x421
1: Valid
Factory
Feature
Address
default
0
×
0x500
4
0x501
Model
0x502
160
AC300 Series Vector Control Inverter Manual
F05.03
Motor rated frequency
0.01~max frequency
F05.04
Motor rated speed
1~65000rpm
F05.05
Motor rated voltage
1~1500V
F05.06
Motor rated current
0.1~3000.0A
Asynchronous motor
F05.07
0.1~3000.0A
no-load current
Asynchronous motor
F05.08
0.01~50.00%
stator resistance
Asynchronous motor
F05.09
0.01~50.00%
rotor resistance
Asynchronous motor
F05.10
0.01~50.00%
stator leakage
Asynchronous motor
F05.11
0.1~2000.0%
stator inductance
synchronous motor
F05.12
0.01~50.00%
stator resistance
Synchronous machine
F05.13
0.01~200.00%
d axis inductance
Synchronous machine
F05.14
0.01~200.00%
q axis inductance
Synchronous machine
F05.15
1~1500V
back EMF
Synchronous machine
F05.16
0.0°~360.0°
encoder installation
F05.17
Reserved
-
0: No operation
Motor parameters
1: Rotary type self-tuning
F05.20
self-adjustment
2: Static type self-tuning
selections
3: Stator resistance self-tuning
LED "0" digit: closed-loop vector
0: OFF
1: ON
Synchronous machine
2: On, only operate firstly when
F05.21
poles searching
electrify
function
LED "00" digit: open-loop vector
0: OFF
1: ON
F05.22
-F05.2
Reserved
9
Function Parameter Table
Model
0x503
Model
0x504
Model
0x505
Model
0x506
Model
0x507
set
Model
0x508
set
Model
0x509
set
Model
0x50A
set
Model
0x50B
set
Model
0x50C
set
Model
0x50D
set
Model
0x50E
set
Model
0x50F
set
Model
0x510
set
0
0x514
0010
0x515
161

Advertisement

Table of Contents
loading

Table of Contents