A01 FM frequency
F03.43
0.00~100.00kHz
output lower limit
A02FM frequency
F03.44
0.00~100.00kHz
output upper limit
F03.45
AO2 extend output
25.0~200.0%
A02 extend analog
F03.46
-10.0%~10.0%
output signal bias
F03.47
A02 extend output
0.000~6.000s
F03.48-
Reserved
F03.49
System parameters
NO.
Function description
Range of settings and definition
0: Not locked
1: Function parameter locked
Parameter and key
F04.00
2: Function parameter and key locked
lock selections
(except for RUN/STOP/JOG)
3: All function parameter and key locked
F04.01
User password
0~65535
F04.0
Reserved
2-
0: No function
1: Send inverter parameters to keyboard
F04.05
Parameter copy
and save
2: Send keyboard parameters to inverter
Remaining value: no operation
LED "0" digit:( Running command,
stop/reset command)
0: Built-in valid, external on valid for
stop/reset command
1:External valid, built-in on valid for
stop/reset command
Keyboard special
2: All valid. Stop/reset command has the
F04.06
function selection
highest priority; invalid when FWD/REV
valid at the same time
LED "00" digit: reserved
LED "000" digit: LCD keyboard
language selection
0: Chinese
1: English
F04.07
Reserved
Function Parameter Table
0.20kH
0x32B
z
50.00k
0x32C
Hz
100.0%
0x32D
0.0%
0x32E
0.010s
0x32F
Factory
Featur
Address
setting
e
0
0x400
0
0x401
0
0x405
0000
0x406
0x407
158
AC300 Series Vector Control Inverter Manual
0: Non-keyboard control mode is invalid
1: Non-keyboard control mode stops
F04.08
STOP key setting
according to stop mode
2: Non-keyboard control mode stop
according to free stop mode
LED "0" digit: keyboard UN/DOWN
key modify selection
0: Invalid
1: Modify frequency setting by key board
numbers F00.08
2: Modify PID give setting by key board
numbers F11.01
UP/DOWN key
F04.09
LED "00" digit: power off storage
selection
selection
0: No save frequency after power off
1: Save frequency after power off
LED "000" digit: action limit
0: Operation stop for adjusting
1: Adjusting only in operation, stop for
F04.10-
Reserved
F04.13
LED "0" and "00" digit: display the
first group
The display content of
00~63
F04.14
the first line in running
LED "000" and "0000" digit: display
state
the second group
00~63
The display content of
F04.15
Same as above
the first line in running
The display content of
F04.16
Same as above
the first line in stop
The display content of
F04.17
Same as above
the first line in stop
The display content of
F04.18
Same as above
the second line in
The display content of
F04.19
Same as above
the second line in
The display content of
F04.20
Same as above
the second line in stop
The display content of
F04.21
Same as above
the second line in stop
LED "0" digit: output frequency
selection
0: Aim frequency
Keyboard display item
F04.22
1: Running frequency
setting
LED "000" digit: power display
dimension
Function Parameter Table
1
0x408
0011
0x409
1101
0x40E
0402
0x40F
1100
0x410
0402
0x411
0402
0x412
1210
0x413
0402
0x414
1210
0x415
0000
0x416
159