Veichi AC300 Series Technical Manual page 20

Hide thumbs Also See for AC300 Series:
Table of Contents

Advertisement

AC300 Series Vector Control Inverter Manual
connect fault
● Keyboard component
damage.
● Baud rate not right.
RS485
● Communication connection
18
communicatio
not right.
n fault
● Communication format not
right.
● Parameter copy
Parameter
communication is fault.
E.CPE
copy fault
● Copy keyboard is not match
the inverter.
The expansion card
Expansion
communicates with the inverter
card
-
for timeout;
connection is
The expansion card does not
abnormal
match the drive.
PG card
PG card and inverter
27
connection is
connection failure
abnormal
PID feedback disconnection
alarm upper limit is set
improperly
PID feedback disconnection
29
PID feedback
alarm lower limit is set
/66
fault
improperly
Lose PID feedback wiring
Feedback sensor failure
Feedback input loop fault
Initial position
31
angle learning
● Check motor parameters
failed
Speed
●Checkout time or check level
32
deviation is
setting is unreasonable
/70
too large
● Motor parameter is abnormal
● FA.27/FA.28 parameter
33
Speed
setting is abnormal
/71
protection
● Motor parameter is abnormal
Fault Diagnoses and Processing
● Seek support from factory.
● Set right Baud rate
● Check communication wiring
● Check Communication
format
● Check wire.
● Select the specified external
keyboard model.
Check the connector and
re-plug the cable;
Use the expansion card of
the specified model.
Check connection
● Confirm the sensor status
and replace the sensor if it is
damaged.
● Correct wiring
● Confirm the set values of
F11.27 and F11.28
● Check the motor parameters;
● Learn after the motor is
stationary;
● Seek technical support from
manufacturers.
● Check the motor parameters
and re-learn again;
● Check the F10.24/F10.25
parameter settings;
● Seek technical support from
manufacturers.
● Check the motor parameters
and re-learn again;
● Check the F10.27/F10.28
36
AC300 Series Vector Control Inverter Manual
● Check the F6 group vector
control parameters
34
Load
● The checkout time or check
/67
protection 1
level setting is unreasonable
35
Load
● The checkout time or check
/68
protection 2
level setting is unreasonable
CPU
36
● CPU timing timeout
time out
GPS lock
72
● GPS timing timeout
machine
GPS
● GPS communication
73
disconnection
disconnection
Fan short
40
● Fan short circuit
circuit
Motor short to
39
● Motor short circuit to ground
ground
Fault Diagnoses and Processing
parameter settings;
● Check the F10.18/F10.19
parameter settings;
● Check the F10.20/F10.21
parameter settings;
● Seek technical support from
manufacturers.
● Seek technical support from
manufacturers.
● Whether the GPS expansion
card is connected properly;
● GPS communication card is
arrears;
● Seek technical support from
manufacturers.
● Check if the fan is smooth
● Check if the motor is shorted
to ground
37