2. C01-Malfunction Diagnosis Monitor Group
Function
Function name
code
C01.00
Malfunction types
C01.01
Malfunction diagnosis information
C01.02
Malfunction running frequency
C01.03
Malfunction output Voltage
C01.04
Malfunction out Current
C01.05
Malfunction Bus Voltage
C01.06
Malfunction module temperature
C01.07
Malfunction machine state
C01.08
Malfunction input terminal status
C01.09
Malfunction output terminal status
C01.10
The last malfunction types
C01.11
The first diagnosis information
C01.12
The last malfunction running frequency
C01.13
The last malfunction output voltage
C01.14
The last malfunction output current
C01.15
The last malfunction bus voltage
C01.16
The
last
malfunction
module
C01.17
The last malfunction machine state
C01.18
The last malfunction input terminal
C01.19
The last malfunction output terminal
C01.20
The first two malfunction types
C01.21
The first two diagnosis information
C01.22
The first three malfunction types
C01.23
The first three diagnosis information
Function Parameter Table
Addres
Unit and definition
s
0x2200
See fault code table
0x2201
See fault code table
0x2202
0.00~Max frequency
0x2203
0~1500V
0x2204
0.1~1000.0A
0x2205
0~3000V
0x2206
0~100℃
LED "0" digit: Running direction
0: FWD
1: REV
LED "00" digit: Running status
0: Stop
1: ACC
0x2207
2: DEC
3:Constant speed
LED "000" digit: Reserved
LED "0000" digit: Reserved
See input terminal chart
0x2208
See output terminal chart
0x2209
Please see malfunction code table
0x220A
Please see malfunction code table
0x220B
0x220C
0.00~Maxfrequecy
0x220D
0~1500V
0x220E
0.1~2000.0A
0x220F
0~3000V
0x2210
0~100℃
LED "0" digit: Running direction
0: FWD
1: REV
LED "00" digit: Running status
0: Stop
0x2211
1: Constant speed
2: ACC
3: DEC
LED "000" digit: Reserved
LED "0000" digit: Reserved
See input terminal chart
0x2212
See output terminal chart
0x2213
0x2214
Please see malfunction information code
0x2215
table
0x2216
0x2217
176
AC300 Series Vector Control Inverter Manual

Appendix 1: AC300 IO Expansion Card Manual

1. AC300IO Expansion Card Introduction

The AC300 inverter has a powerful expansion functions. The AC300IO1 expansion card is a terminal expansion card
that can be used in our AC300 full range of inverters. Enriched the input and output terminal functions of the inverter
can meet the needs of various applications in specific situations.
2. AC300IO Card Ordering Model
Product order model: AC300IO1
3. AC300IO Expansion Card Instructions
Product technical parameters
Digital input signal characteristics
Category
Signal name
Response frequency range
Input
X6,X7,X8,X9
0-50KHz
signal
X10
0-50KHz
Digital output signal characteristics
Category
Signal name
output method
Y2
NPN collective tube open collector output
Output
TA2,TB2,TC2
signal
Relay normally open normally closed output
PT100 thermocouple analog input signal characteristics
Category
Signal name
PT100 Signal
PK+/PK-
Differential two-wire input

Terminal Function Introduction

The AC300IO1 expansion card terminal arrangement is shown in the following figure:
AC300 IO Expansion Card Manual
input resistance
Effective level range
About 4.4 KΩ
High
level:10V~-30V
About 1.5 KΩ
Low
level:0V~-8V
Maximum output
DC24V/50mA
3A/240VAC
output method
Detection temperature range
0℃-200℃
177

Advertisement

Table of Contents
loading

Table of Contents