C01-Malfunction Diagnosis Monitor Group

Press the PRG button for 2 seconds or more to enter the "C00" parameter group and press the up button to
enter the "C01" parameter group. Check the current status of the drive.
Function code
Function name
C01.00
Malfunction types
C01.01
Malfunction diagnosis information
C01.02
Malfunction running frequency
C01.03
Malfunction output Voltage
C01.04
Malfunction out Current
C01.05
Malfunction Bus Voltage
C01.06
Malfunction module temperature
C01.07
Malfunction machine state
C01.08
Malfunction input terminal status
C01.09
Malfunction output terminal status
C01.10
The last malfunction types
C01.11
The first diagnosis information
C01.12
The last malfunction running frequency
C01.13
The last malfunction output voltage
C01.14
The last malfunction output current
C01.15
The last malfunction bus voltage
C01.16
The last malfunction module temperature
C01.17
The last malfunction machine state
C01.18
The last malfunction input terminal state
C01.19
The last malfunction output terminal state
C01.20
The first two malfunction types
C01.21
The first two diagnosis information
Function Parameter Specifications
Unit and definition
Address
See fault code table
0x2200
See fault code table
0x2201
0.00~Max frequency
0x2202
0~1500V
0x2203
0.1~1000.0A
0x2204
0~3000V
0x2205
0~100℃
0x2206
LED "0" digit: Running direction
0: FWD
1: REV
LED "00" digit: Running status
0: Stop
1: ACC
0x2207
2: DEC
3:Constant speed
LED "000" and "0000" digit :
Reserved
See input terminal chart
0x2208
See output terminal chart
0x2209
Please see malfunction code table
0x220A
Please see malfunction code table
0x220B
0.00~Maxfrequecy
0x220C
0~1500V
0x220D
0.1~2000.0A
0x220E
0~3000V
0x220F
0~100℃
0x2210
LED "0" digit: Running direction
0: FWD
1: REV
LED "00" digit: Running status
0: Stop
0x2211
1: Constant speed
2: ACC
3: DEC
LED "000" and "0000" digit :
Reserved
See input terminal chart
0x2212
See output terminal chart
0x2213
0x2214
Please see malfunction information
0x2215
106
AC300 Series Vector Control Inverter Manual
C01.22
The first three malfunction types
C01.23
The first three diagnosis information
F04.18
Keyboard display parameter 5
F04.19
Keyboard display parameter 6
F04.20
Keyboard display parameter 7
F04.21
Keyboard display parameter 8
It is valid only when the keyboard is double-lined, and is used to display the parameter selection on the second line
of the keyboard. The two-line keyboard switches between the display parameters 5-8 of the second line of the keyboard
by the " " key.
For details, see the parameters [F04.14~F04.17].
F04.22

Keyboard display selections

Setting range: 0000-1111
LED "0" digit: output frequency selection
0: Aim frequency Display the aim frequency of current control motor
1: Actual frequency Display the output frequency of inverter
LED"00" digit: Reserved
LED"000" digit: Power display dimension To correct the output frequency of C-10.Can select the unit of the power
0: Power display ratio (%) Display the ratio of output power,100% corresponds with the rated motor power.
1: Power display Kilowatt (KW) Display the actual power
LED"0000" digit: reserved
LED "0"
digit: self-tuning display monitoring parameters
0: Invalid 1: Valid
LED "00"
digit: C05 group display selection
Monitor display
F04.23
0-1: VF mode related parameters
selection
2: VC mode related parameters
LED "000"
digit: C00.40~C00.69 display selection
0: Do not display 1: Display
F04.24
Rotate speed display coefficient
Setting range: 0.0-500.0%
It sets the display coefficient of keyboard monitor item "machine speed" .100% is corresponding to motor rated
speed.
F04.25
Power display coefficient
Setting range: 0.0-500.0%
This parameter sets the display coefficient ratio of the keyboard monitor item "output power"; for example, when the
Function Parameter Specifications
code table
0x2216
0x2217
Same as above
Factory set: 0002
Same as above
Factory set: 0004
Same as above
Factory set: 001
Same as above
Factory set: 0012
Factory set: 0000
Factory
default: 0000
Factory set: 100.0%
Factory set: 100.0%
107

Advertisement