Speed deviation
F10.42
excessive detection
(0x0A2A)
time
F10.43
Speed protection
(0x0A2B)
action
F10.44
Speed exceed
(0x0A2C)
detection threshold
F10.45
Speed exceed
(0x0A2D)
detection time
F10.5x:Fault Recovery Protection
Parameter
Name
(Address)
F10.50
Fault self-recovery
(0x0A32)
F10.51
Fault self-recovery
(0x0A33)
interval
F10.52
Number of fault
(0x0A34)
recovered
4.14 F11:Operator Parameter
F11.0x:Button Operation
Parameter
Name
(Address)
F11.00
Key lock selection
(0x0B00)
F11.01
Key lock password
(0x0B01)
Keyboard
F11.02
multi-function key
(0x0B02)
selection
F11.03
Keyboard STOP
(0x0B03)
button settings
Status interface up and
F11.04
down keys (knob)
(0x0B04)
function selection
AC310 Series Frequency AC Drive Manual
V/F SVC FVC PMVF PMSVC PMFVC
Set the detection time of the excessive speed deviation, when the
speed deviation is excessive and the duration is longer than this
time value the deviation warning reported
V/F SVC FVC PMVF PMSVC PMFVC
Set the alarm detection mode selection and alarm mode selection
when the motor is overspeed
Unit: Check out the selection
0: No detection 1: Only at constant speed detection 2: Always
detected
Ten places: alarm selection
0: Free stop and report fault 1: Alarm and continue to run
V/F SVC FVC PMVF PMSVC PMFVC
Set the speed exceed warning detection value, which corresponds
to F01.10 [maximum frequency]
V/F SVC FVC PMVF PMSVC PMFVC
Set the duration of the detection of the flying speed, the feedback
speed is greater than F10.44 and continue for that time, and the
speed warning is detected.
Content
V/F SVC FVC PMVF PMSVC PMFVC
Set the allowable times of fault self-recovery.
Note: the value of 0 indicate the function is turn off otherwise the
function is enable
V/F SVC FVC PMVF PMSVC PMFVC
Set the waiting time from fault to reset
V/F SVC FVC PMVF PMSVC PMFVC
This value indicates the number of self-recovery that have been
performed. This parameter is a read-only parameter.
Content
V/F SVC FVC PMVF PMSVC PMFVC
0: No lock 1: Keyboard function parameter modification lock
2: Function parameters and non-start and stop button lock 3:
function parameters and button full lock
V/F SVC FVC PMVF PMSVC PMFVC
Set the key lock password
V/F SVC FVC PMVF PMSVC PMFVC
0: Invalid 1: Reverse run key
2: Forward jog run key 3: Reverse jog run key
4: Keyboard command channel and terminal naming channel
switch
5: Keyboard command channel and communication naming
channel switch
6: Terminal command channel and communication naming channel
switch
7: keyboard, terminal, communication command channel cycle
switching
V/F SVC FVC PMVF PMSVC PMFVC
0: Non-keyboard control mode is invalid
1: Non-keyboard control mode stops according to stop mode
2: Non-keyboard control mode stops in free mode
V/F SVC FVC PMVF PMSVC PMFVC
Unit keyboard up and down keys to modify the selection
0: Invalid 1: Used to adjust the frequency keyboard given F01.09
2: used to adjust the PID keyboard given F13.01
3: Keyboard up and down keys to modify the parameter number
35
2s
STOP
(0 ~60)
0002
STOP
(0000 ~0012)
110.0%
STOP
(0 ~150.0%)
0.010s
STOP
(0 ~2.000)
Factory default
Adjustable
(range)
properly
0
STOP
(0 ~10)
1.0s
STOP
(0 ~100.0)
0
READ
Factory default
Adjustable
(range)
properly
0
RUN
(0 ~ 3)
0
RUN
(0 ~ 65535)
0
STOP
(0 ~ 7)
0
STOP
(0 ~ 2)
0011
STOP
(0000~0213)