Veichi AC300 Series Technical Manual page 85

Hide thumbs Also See for AC300 Series:
Table of Contents

Advertisement

AC300 Series Vector Control Inverter Manual
Output voltage source of
F08.31
voltage-frequency
0.0%~100.0%
separation number setting
Output voltage source of
F08.32
voltage-frequency
0.0~100.00s
separation ACC time
Output voltage source of
F08.33
voltage-frequency
0.0~100.00s
separation DEC time
0:Output voltage and frequency
ACC/DEC no interaction
voltage-frequency
F08.34
1: Output voltage down to 0V,
separation stop time
then output frequency start to
Protection and Malfunction Parameter Group
NO.
Function description
Range of settings and definition
0: Suppression valid
OC suppression
F10.00
1: ACC/DEC valid, constant speed
function
F10.01
OC suppression point
0.0~300.0%
F10.02
OC suppression gain
0.0~500.0%
LED "0" digit: CBC(cycle by cycle,
limit current according to its
waveform)
0: off
1: on
LED"00" digit: OC protection
interference suppression
Current hardware
F10.03
0: off
1: First grade 2: Second
protection settings
grade
LED"000"digit: SC protection
interference suppression
0: off
1: First grade 2: Second
grade
LED"0000"digit: Reserved
F10.04
Reserved
F10.05
Hardware protection
0: Invalid
LED"0" digit: Over voltage
suppression
0: Invalid
Bus over voltage
2: Valid both in ACC/DEC
F10.06
suppression function
LED"00" digit: Over-excitation
control
0: off
LED"000"/"0000": Reserved
Function Parameter Table
0.0%
0x81F
10.00s
0x820
10.00s
0x821
0
0x822
Factory
Feature
Address
default
0
0xA00
160.0%
0xA01
100.0%
0xA02
0001
0xA03
0xA04
1: Valid
0xA05
1: Valid in DEC
0012
0xA06
1: on
166
AC300 Series Vector Control Inverter Manual
Bus over voltage
F10.07
110.0~150.0%
suppression point
Bus over voltage
F10.08
0.0~500.0%
suppression gain
Bus under voltage
0: Invalid
F10.09
suppression function
1: Valid
Bus under voltage
F10.10
60.0~90.0%
suppression point
Bus under voltage
F10.11
0.0~500.0%
suppression gain
Bus under voltage
F10.12
60.0~90.0%
protection point
Phase missing
F10.13
0~100%
LED "0" digit: Earth short-circuit
detection after power on
Short-circuit detection
0: off
1: on
F10.14
after power on
LED"00" digit: Fan short-circuit
detection after power
0: off
1: on
LED"0" digit: Output phase
missing protection
0: off
1:on
phase missing
LED"00" digit: Input phase
F10.15
protection
missing protection
0: off
1: Open Alarm
2: Open Fault(STOP VFD)
LED"000" /"0000" digit: Reserved
Motor overload
F10.16
0.0~250.0%
protection curve
Function Parameter Table
128.0%
0xA07
100.0%
0xA08
0
0xA09
80.0%
0xA0A
100.0%
0xA0B
60.0%
0xA0C
10.0
0xA0D
11
0xA0E
0021
0xA0F
100.0%
0xA10
167

Advertisement

Table of Contents
loading

Table of Contents