the inverter will process according to the upper limit of AI1.

The AI1 upper limit corresponds setting:

It is used to set the percentage of the set value corresponding to the AI1 upper limit input analog quantity.

AI1 filtering time:

This parameter is defined as the size of the (AI1) input analog signal to filter out the interference signal. The longer
the filtering time, the stronger the anti-interference ability, but the reaction speed becomes slower; the shorter the
filtering time, the weaker the anti-interference ability, but the reaction speed becomes faster.
Tips: Set the frequency source to select AI1 timing, the set frequency can be adjusted to a negative value, and
the [F00.16] hundred-bit selection frequency control direction can be matched to perform bipolar adjustment.
F03.06
AI2 Lower limit
F03.07
AI2 Lower limit corresponding setting
F03.08
AI2 upper limit
F03.09
AI2 upper limit corresponding setting
F03.10
AI2 filter time
F03.11
Reserved
See the description of AI1.
F03.12
AI1 function selection
F03.13
AI1 high level setting
F03.14
AI1 low level setting
F03.15
AI2 function selection
F03.16
AI2 high level setting
F03.17
AI2 low level setting
The function selection of AI1 and AI2 terminals is the same as the multi-function input X1~X10 on the control panel. It
can be used as a multi-function digital input. For detailed settings, please refer to [F02.00~F02.09].
Function Parameter Specifications
Setting range: 0.00~10.00V
Default: 0.00V
Setting range: -100.00~100.00%
Default: 0.00%
Setting range: 0.00~10.00V
Default: 10.00V
Setting range: -100.00~100.00%
Default: 100.00%
Setting range: 0.00~10.00s
Default: 0.100s
Setting range: 0~63
Default: 0
0.00~100.00%
70.00%
0.00~100.00%
30.00%
Setting range: 0~63
Default: 0
0.00~100.00%
70.00%
0.00~100.00%
30.00%
94
AC300 Series Vector Control Inverter Manual
AI1, AI2 high level setting: The port sampling value is considered to be high level if it is greater than or equal to the
set value.
AI1, AI2 low level setting: The port sampling value is considered to be low level if it is less than or equal to the set
value.
The AI1 port sampling filter value is adjusted by the curve, 0.00~10.00V corresponds to 0~100.00%
The AI1 port sampling filter value is adjusted by the curve, 0.00~20.00 MA corresponds to 0~100.00%
If AI is used as voltage input, 0.00~10.00V corresponds to 0~100.00%.
If AI is used as current input, 0.00~20.00 MA corresponds to 0~100.00%
F03.18
Valid state setting when analog used as terminal
LED "0" digit: AI1
0: low level
1: high level
LED "00" digit: AI2
0: low level
1: high level
LED "000" digit: Reserved
LED "0000" digit: Reserved
F03.19
Analog input curve selection
LED "0" digit: AI1
LED "00" digit: AI2 (selectable voltage or current input via switch on the control board)
0: Straight line By default, the usual two-point line can be referred to the "analog given frequency diagram" above.
1: Curve 1 Multi-point stitching please see the description of function code [F03.21~F03.28].
2: Curve 2 Multi-point stitching please see the description of function code [F03.29~F03.36].
F03.21
Curve 1 lower limit
F03.22
Curve 1 lower limit corresponding setting
F03.23
Curve 1 inflection point 1 input voltage
Curve 1 inflection point 1 corresponding
F03.24
setting
F03.25
Curve 1 inflection point 2 input voltage
Curve 1 inflection point 2 corresponding
F03.26
setting
F03.27
Curve 1 upper limit
F03.28
Curve 1 upper limit corresponding setting
F03.29
Curve 2 lower limit
Function Parameter Specifications
Setting range: 0000~0011
Default: 0000
Setting range: 0000~0222
Default: 0000
Setting range: 0.00~10.00V
Default: 0.00V
Setting range: 0.00~100.00%
Default: 0.00%
Setting range: 0.00~10.00V
Default: 3.00V
Setting range: 0.00~100.00%
Default: 30.00%
Setting range: 0.00~10.00V
Default: 6.00V
Setting range: 0.00~100.00%
Default: 60.00%
Setting range: 0.00~10.00V
Default: 10.00V
Setting range: 0.00~100.00%
Default: 100.00%
Setting range: 0.00~10.00V