Led “00” Digit: Terminal Command Bundle; Led “000” Digit: Communication Command Bundle; Led “0000” Digit: Optional Card Command Bundle; Maximum Frequency - Veichi AC300 Series Technical Manual

Hide thumbs Also See for AC300 Series:
Table of Contents

Advertisement

AC300 Series Vector Control Inverter Manual
[F00.16] LED hundred-bit frequency direction control is still valid.
LED "0" digit: keyboard command bundle
0: No binding Press the [F00.03~F00.06] setting to determine the frequency reference.
1: keyboard digital given frequency
2: Reserved
3: Voltage / current analog AI1 given
4: Voltage/current analog AI2 given
5 reservations
6: Terminal pulse PUL given
7: RS485 communication given
8: Terminal UP/DW control
9: PID control given
A: Program control PLC given
B: Option card
C: multi-speed speed given
D: Reserved
The above 1~12 items are the same as the frequency given channel A selection [F00.03].
LED "00" digit: terminal command bundle
The setting range of 1~12 is the same as the LED ones: the keyboard command instruction bundle description is
consisten
LED "000" digit: Communication command bundle
The setting range of 1~12 is the same as the LED ones: the keyboard command instruction bundle description is
consistent.
LED "0000" digit: Optional card command bundle
The setting range of 1~12 is the same as the LED ones: the keyboard command instruction bundle description is
consistent.
Examples: If remote/in-place switching is used, the remote mode uses the communication command reference and
frequency reference. The local mode uses the terminal command reference and the keyboard digital frequency
reference.
The setting parameters are as follows: [F00.02=2: Communication Control] [F00.03=6: Communication Reference]
[F00.07=0010: Ten-digit terminal command command bundled keyboard digital reference frequency] [F02.04=49 :
Command channel is switched to terminal].
Function Parameter Specifications
58
AC300 Series Vector Control Inverter Manual
F00.08
Keyboard digital setting frequency
Set range: 0.00~Upper limit frequency
This parameter is valid when the frequency reference channel [F00.03, F00.04] is set to "0: Keyboard Digital
Reference" and is used to set and modify the keyboard digital setting frequency.
F00.09
Max frequency output
Setting range: Upper limit frequency~600.00Hz
Upper limit frequency
F00.10
Setting range: 0~7
source selection
Upper frequency limit
Setting range: Lower limit frequency~Max
F00.11
digital setting
frequency
F00.12
Lower limit frequency
Setting range: 0.00~Upper limit frequency
Lower limit frequency
F00.13
Setting range: 0~1
running mode

Maximum frequency:

When the analog input, pulse input (PUL), multi-speed, etc. in the inverter are used as the frequency source, 100%
of each is the relative maximum frequency calibration; when the [F01.16] LED bits are set to "0", the maximum The
frequency is used as the reference frequency for the acceleration/deceleration time.
Upper frequency source selection:
Select a given source for the upper limit frequency of the drive. The upper limit frequency is the upper limit of the
given frequency and limits the given frequency.
0: Upper limit frequency digital reference Set by parameter [F00.11].
1: reserved
2: voltage / current analog AI1 given
3: voltage / current analog AI2 given
4: Reserved
5: terminal pulse PUL given
6: RS485 communication setting Set by address 0x3004/0x2004, please refer to Appendix 2: Modbus
Communication Protocol
7: Option card
When using keyboard potential, analog (AI1, AI2), terminal pulse (PUL), RS485 communication reference, and
optional card, similar to frequency reference channel A, please refer to [F00.03].
Upper limit frequency digital setting:
The upper limit frequency is given to the channel when [F00.10] is set to "0".
Function Parameter Specifications
Default: 50.00Hz
Default: 50.00Hz
Default: 0
Default: 50.00Hz
Default: 0.00Hz
Default: 1
59