Ao Output Gain; A0 Output Signal Offset; A0 Output Filtering - Veichi AC300 Series Technical Manual

Hide thumbs Also See for AC300 Series:
Table of Contents

Advertisement

AC300 Series Vector Control Inverter Manual
Corresponding to the
mechanical speed
5
Machine speed
corresponding to the
output frequency of the
Corresponding to the
6
Given torque
output torque of the
current inverter
Corresponding to the
7
Output torque
output torque of the
current inverter
Corresponding to the PID
8
PID given value
given by the current
inverter
Corresponding to the PID
9
PID feedback value
feedback amount of the
current inverter
Corresponds to the
10
Output power
output power of the
current inverter
Corresponds to the input
11
Bus voltage
voltage of the current
inverter
Corresponds to the
12
AI1
current AI1 input value of
the inverter
Corresponds to the
13
AI2
current AI input value of
the inverter
Corresponds to the AS
14
AS input
input value of the current
inverter
Corresponds to the PUL
15
PULoutput value
input value of the current
inverter
Function Parameter Specifications
The maximum output
The minimum output
corresponds to the speed
corresponds to 0rpm
corresponding to the
maximum frequency
The minimum output
The maximum output
corresponds to a torque
corresponds to 200% of the
of 0.00%
torque
The minimum output
The maximum output
corresponds to a torque
corresponds to 200% of the
of 0.00%
torque
The minimum output
The maximum output
corresponds to 0.00%
corresponds to 100% PID
PID given
given
The minimum output
The maximum output
corresponds to 0.00%
corresponds to 100% of the
PID feedback
PID feedback amount
Maximum output
The minimum output
corresponds to rated output
corresponds to 0 power
power
The maximum output
The minimum output
corresponds to twice the
corresponds to 0V
rated DC voltage of the
The minimum output
The maximum output
corresponds to the AI1
corresponds to the upper
input lower limit
limit of the AI1 input.
The minimum output
The maximum output
corresponds to the AI
corresponds to the upper
input lower limit
limit of the AI input.
The minimum output
The maximum output
corresponds to the AS
corresponds to the upper
input lower limit
limit of the AS input.
The minimum output
The maximum output
corresponds to the PUL
corresponds to the upper
input lower limit
limit of the PUL input.
98
AC300 Series Vector Control Inverter Manual
Corresponds to the
16
Module temperature 1
module temperature 1 of
the current inverter
Corresponds to the
17
Module temperature 2
module temperature 2 of
the current inverter
AO address 0x3019
/0x2019
18
RS485 given
AO2 address 0x301A
/0x201A
F03.40
A01 output gain
Setting range : 0.0~200.0%
F03.41
A01 analog output signal bias
Setting range : -10.0~10.0%
F03.42
A01 output filter
Setting range : 0.000~6.000s

AO output gain:

The value used to adjust the analog output of the (AO) terminal.

A0 output signal offset:

Used to adjust the zero point of the (AO) terminal output signal.
AO analog output and gain, offset schematic

A0 output filtering:

This parameter is defined as the size of the AO1 output analog signal filtered to eliminate the interference signal. The
Function Parameter Specifications
The minimum output
The maximum output
corresponds to the
corresponds to the module
module temperature 1 is
temperature 1 is 100
0 degrees Celsius
degrees Celsius
The minimum output
The maximum output
corresponds to the
corresponds to module
module temperature 2 is
temperature 2 of 100
0 degrees Celsius
degrees Celsius
Minimum output
The maximum output
corresponds to 0
corresponds to 1000
Default : 100.0%
Default : 0.0%
Default : 0.010s
99