Chapter 4 Function Parameter Table

"●": Means that the parameter can be revised during frequency inverter in a running state;
"〇": Means that the parameter can not be revised when in a running state
"×": Means that the parameter can be read but not revised;
"–":Means that the parameter is "manufacturer parameter" and only set by the manufacturer;
Basic parameter
Function
No.
description
F0.00
Control mode
F0.01
Application type
Run command
F0.02
channel
Frequency given
F0.03
main channel
selection
F0.04
Main channel gain
Frequency given
F0.05
auxiliary channel
selection
F0.06
Auxiliary channel gain
Combination of main
F0.07
channel and auxiliary
channel
AC80T Tower Crane Purpose VFD Manual
Range of setting and definition
1: VC without PG 1
2: VC with PG 1
0: Hositing mechanism
1: Slewing mechanism
2: Trolley travelling mechanism
0: Keyboard control
1: Terminal control
2: RS485 communication control
0: Keyboard no. given
6:RS485communication port
given
0.00~5.000
0: Keyboard no. given
1: Keyboard potentiometer given
6:RS485 communication port
given
0.00~5.000
LED "0" digit: Combination mode
selection
0: Main channel efficiency
1: Auxiliary channel efficiency
2: Main+auxiliary
3: Main-auxiliary
4: MAX{main,auxiliary}
5: MIN{ main,auxiliary }
6: Main×auxiliary
LED "10" digit: Frequency control
direction selection
0: Frequency control direction
invalid
1: Frequency control direction
valid
LED "100" digit: Reserve
LED "1000" digit: Reserve
15
Factory
Property
default
1
0
1
0
1.000
1
1.000
0000