1. Installation
Mounting
1−6
Note
For the CPX−SF34/35, use only metal interlinking blocks
and suitable screws:
For metal interlinking blocks:
screws with metric thread.
Mount the control block as follows:
1. Check seal and seal surfaces
2. Insert the control block without tilting into the first
interlinking block of the CPX terminal (counted from the
left).
3. Carefully press the control block into the interlinking
block up to the stop.
4. Place the screws so that the self−cutting threads can be
used.
5. Tighten the screws with a size T10 TORX screwdriver with
a torque of 0.9 ... 1.1 Nm.
Festo P.BE−CPX−SF34+SF35−E N en 1007NH