Siemens Sinumerik 802D sl Instruction Manual page 237

Hide thumbs Also See for Sinumerik 802D sl:
Table of Contents

Advertisement

Climatic ambient conditions
The control system can be used under the following climatic ambient conditions:
Temperature
Relative humidity
Air pressure
Pollutant concentration
Mechanical ambient conditions
The mechanical ambient conditions for the control system are specified in the table below in
the form of sinusoidal waves.
Mechanical ambient conditions
Vibration tested in accordance
with DIN EN 60068-2-68
Shock resistance tested in accor-
dance with DIN EN 60068-2-27
Vibration reduction
If the control system is subjected to major impacts or vibration, appropriate measures must
be taken to reduce the acceleration or the amplitude of the vibration.
We recommend mounting the control system on shock-absorbing material (e.g. vibration-
absorbing metal).
Siemens Automation Parts
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
Ambient conditions
From 0 to 50 _C
5 to 95%,
1,080 ... 795 hPa
SO
Relative humidity < 60%, without
condensation
H
Relative humidity < 60%, without
condensation
B.3
Mechanical and climatic ambient conditions for operation
Fields of application
: < 0.5 ppm;
2
S: < 0.1 ppm;
2
Operation
10 to 58 Hz: 0.35 mm
58 to 200 Hz: 50 m/s
10 g peak value, 6 ms duration
100 shocks in each of the 3
axes vertical to one another
Standards and Approvals
Remarks
With a simultaneity of 50 %
Without condensation, corres-
ponds to relative humidity (RH)
severity level 2 in accordance
with IEC 1131-2
Tested:
10 ppm; 4 days
1 ppm; 4 days
Transport (in packaging)
5...9 Hz: 3.5 mm
2
9 to 200 Hz: 10 m/s
10 g peak value,
6 ms duration
100 shocks in each of the
3 axes vertical to one another
2
B-235

Advertisement

Table of Contents
loading

Table of Contents