Interfaces
4.1
CNC operator panel (PCU) interfaces
4.1.5

PROFIBUS DP interface

The CNC operator panel (PCU) communicates with the I/O modules via the PROFIBUS DP
interface.
The PROFIBUS DP protocol is used for the communication.
The baud rate of the PROFIBUS DP interface is 12 Mbit/s; the baud rate cannot be chan-
ged. Converters for optical fiber cable (OLMs, OLPs) or repeaters are not permitted.
The operator panel CNC provides master functionality.
Female connector pin assignment
Designation:
Type:
Table 4-3
Schematic view of the female
connector, mounting position
and labeling
The CNC operator panel has a fixed PROFIBUS DP address.
The addresses of the PP 72/48 I/O modules must be set using the DIL switches S1
(see Section 7.12).
4-22
X6
(DP)
9-pin D-Sub socket connector
Pin assignment of female connector X6
Pin
1
DP
X6
X6
2
1
3
4
9
5
6
7
8
9
Name
not
assigned
M24
24 V reference potential (teleservice)
B
Data input/output (RS485)
RTS
Transmission request
M5
5 V reference potential
P5
5 V power supply 90 mA, short-circuit-proof
P24
24 V power supply (teleservice) 150 mA, short-
circuit-proof, not isolated
A
Data input/output (RS485)
not
assigned
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition