7. Click on Finish. The new project with the drive unit will be displayed in STARTER (see
10.3.2
Acquiring the component topology and configuring the drive unit
automatically
After you have created the project and acquired the drive unit with its PROFIBUS address
ONLINE, you must now acquire the appropriate component topology and configuration of
the drive unit ONLINE.
Fig. 10-49 Project_1
1. Select the drive unit Drive_unit_Addr5 in the Project Navigator.
2. Select Connect to target system.
3. Select the drive unit Drive_unit_Addr5 in the Project Navigator.
4. Choose the Restore factory settings function key (see screenshot below).
Fig. 10-50 Restoring the default settings
Siemens Automation Parts
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
Fig. 10-49)
2. Select
Connect to target system.
1. Select the drive unit
Drive_unit_Addr5.
10.3
Creating a drive project ONLINE
4. Select
Restore default settings.
Creating a Drive Project
10-153