Parker TPDM User Manual page 118

Table of Contents

Advertisement

Parker Hannifin Manufacturing Srl
Follows a representation of management:
Parameters:
Par.
Pr252
Delay time to operational enable (brake opened).Using
the DS402 protocol, in remote, this value is insert at the
start-up of the drive into the object 0x2068.
Pr253
Delay time to operational disable (brake closed).Using
the DS402 protocol, in remote, this value is insert at the
start-up of the drive into the object 0x2066.
Par.
b251.6 Brake management. (1) function enabled, the brake is command in
according to the logical internal of the drive or by to the external
control.
b251.7 Brake logical. (0) the firmware of the drive commands the output to
insert or release the motor brake. (1) the function is management by
external control, in this status is preserved the compatibility of the
previous systems.
Description
Description
user's manual TPDM
field
Def. Type
Unit
Note
1count=
0
R/W
6,144ms
1count=
0
R/W
6,144ms
Def. Type
Note
0
R/W
0
R/W
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents