Page 1
Parker SSD Drives company without written permission from Parker SSD Drives, a division of Parker Hannifin Ltd . Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions.
Page 2
All manuals and user guides at all-guides.com Safety Information WARNING! During commissioning, remove the fuses (or trip the circuit breaker) on your 3- phase supply. Make sure the power is OFF, and that it cannot be switched on accidentally whilst you are working.
Page 3
All manuals and user guides at all-guides.com Safety Information CAUTION! At any time, there may be a loss of motor control and separate/independent application measures should be taken to ensure that such loss of motor control cannot present a safety hazard.
PEED EEDBACK PTION Description The 8902/RE and 8902/RR Resolver Speed Feedback Options allow resolvers to be connected directly to the motor controller to provide highly accurate speed feedback measurement. In addition, the 8902/RR provides an emulated pulse encoder output. Features The Option has the following features: •...
All manuals and user guides at all-guides.com Specifications – Resolver Interface (8902/RE and 8902/RR) Maximum Speed 8902/RE: Up to 50,000RPM (with 2 pole resolver ) 8902/RR: Up to 30,000RPM (with 2 pole resolver ) Carrier Output Signal 7Vrms, 8kHz Maximum Carrier Supply...
9. Replace the control board (with attached Options) into the drive. 10. Tighten the Option A and Option B screws; or importantly, fit the blank covers and secure with the screws. Figure 3 Rear of Control Board 8902/RE Resolver Speed Feedback Option...
Vin = V(R1-R2) : carrier signal ( reference voltage ) TR = transformation ratio ϕ = position Approved Resolvers Parker SSD Drives approve the following Resolvers for use with the 8902/RE Speed Feedback Option. Tamagawa TS2610N71E64 Tamagawa TS2620N701E11 Tamagawa TS2620N861E11...
Clockwise rotation of the encoder shaft normally causes channel A to lead channel B, but this could reverse depending on the resolver wiring. 1 encoder line 1024 encoder lines = 1 complete revolution of resolver 8902/RE Resolver Speed Feedback Option...
All manuals and user guides at all-guides.com Initial Set-up Configuring the 890 Drive The DSE 890 Configuration Tool is Parker SSD Drives’ Windows-based block Note: programming software and is supplied with each drive. Use the DSE 890 Configuration Tool to configure the RESOLVER function block, as detailed below.
Page 13
SPEED FILTER Range : 10.0 to 1000.0 Hz This input allows you to select the cutting frequency of the first order low pass filter applied to the resolver speed output. 8902/RE Resolver Speed Feedback Option...
♦ The resolver must be adjusted in a way to give a position of 0 degrees when the M1 motor phase crosses the 0 Volt line in a rising variation. For example, a 6 pole motor associated with a 2 pole resolver will give the following curves: -100 -150 -200 position(degree) M1 phase 8902/RE Resolver Speed Feedback Option...
Page 15
All manuals and user guides at all-guides.com ECN No. DATE DRAWN CHK'D ISS. MODIFICATION Add support for 8902/RR 17852 27/08/09 FIRST USED ON MODIFICATION RECORD 8902/RE and 8902/RR Resolver Speed Feedback Options DRAWING NUMBER SHT. 1 ZZ469251C002 OF 1 8902/RE Resolver Speed Feedback Option...