2. Technical Data

2.1 Specifications

Linescanner
Type
Temperature range:
Optical resolution (90% energy)
Spot detection (50% energy)
Spectral response:
Scan angle (FOV):
Accuracy:
Repeatability:
Detector:
Sampling rate:
Standard focal distance:
Mechanical scanning system:
Power requirement:
Protection rate:
Ambient temperature range:
(for scanner with housing)
- without cooling:
Warm-up time:
System
Scan lines:
Min. kiln speed:
Max. kiln speed:
Packaging:

2.2 Scope of Delivery

The standard CS211 package includes:
Scanner:
at 20 Hz scan speed
1
at 20 Hz scan speed
2
CS210
MP150HR linescanner
100 to 650°C (212 to 1202°F)
170 : 1 (IFOV = 5,9 mrad)
510 : 1 (IFOV = 2,0 mrad)
3.5 to 4 µm
90°
± 0.5% of reading or ± 3°C (± 6°F)
at 0 - 50°C (32 - 122°F) ambient temperature for the scanner
± 1°C (± 2°F),
at 0 - 50°C (32 - 122°F) ambient temperature for the scanner
HgCdTe
1024 pixel per scan line
infinity
MTBF: 40,000 hours
100 to 240 VAC (for the system connection box in the field)
IP65 (NEMA4) protection for linescanner
-40 to 45°C (-40 to 113°F), no direct sunlight
20 minutes
200
0.02 rpm (for synchronized measurement)
6 rpm @ 200 lines @ 20 Hz scan speed
(for synchronized measurement)
CS211: about 40 kg (88 lb)
CS212: about 80 kg (176 lb)
Linescanner MP150HR
(CS212: 2 units, CS213: 3 units, CS214: 4 units)
7.5 m (24.6 ft) Ethernet cable
7.5 m (24.6 ft) power cable
Rev. B4 Feb 2015
Technical Data
1
2
whichever is greater,
9

Hide quick links: