Coolant Leak Trouble-Shooting - ESAB 100i Instruction Manual

Plasma systems
Hide thumbs Also See for 100i:
Table of Contents

Advertisement

100i / 200i / 300i / 400i

7.05 Coolant Leak Trouble-Shooting

Never operate the system if coolant leaks from the torch. A steady drip indicates that torch parts are damaged or installed im-
properly. Operating the system in this condition can damage the torch head. Refer to the following chart for guidance on coolant
leakage from the torch head.
Torch leaks
Are Torch
Consumable Parts
Installed?
Yes
Are Parts New
or Used?
New
Are Parts fully
assembled into
the Torch?
Unsure?
Disassembly fully
and re-assemble
the Torch Properly.
See Installation Manual.
Art # A-09638
76
Leaking from
Coolant Supply or
No
Coolant Return?
Used
Yes
Is the Torch Damaged?
Yes
Replace Torch Head
Torch
Electrodes
TORCH INFORMATION
Order Coolant
Return
Supply
Tube Replacement Kit
The parts probably are worn out.
See chart for approximate life expectancy.
The torch may be damaged. See page
to determine if head damage has occurred.
Remove and Lubricate
all O-rings on Torch Head,
Consumables Cartridge,
No
and Consumables.
Re-assemble Torch.
Still leaks?
Yes
Replace Consumable
Yes
Cartridge and Shield Cup.
Torch still leaks?
Art # A-09653
Check Valve
Kit 9-4846
Order Coolant
0560956430