Code
Message
401
Coolant Level low
402
Low coolant flow
403
Coolant overheated
Coolant System not
404
ready.
Low Coolant Level
405
Warning
Coolant Flow Low Warn-
406
ing
Coolant overheated, high
407
ambient.
Code
Message
501
CANBUS Acknowledge
Fault
502
CANBUS Off
503
CANBUS Errors Warning
504
Reserved
0560956430
CCM Status Code
Group 4 -- Torch Coolant System
Check coolant level, add as needed. Defective or disconnected level sensor.
Coolant flow as measured by flow switch FS1 is less than 0.7 gpm; Clogged filter;
Restriction in torch lead or head; Wrong style consumables; Bad O-ring on the torch
check valve; broken or defective torch coolant tube/check valve; Defective pump or
bypass valve. 402 code along with 104 code is probably a low flow problem.
Coolant supply temperature exceeded 75 degrees Celsius (167F). Operating with
side panel loose or removed; Air flow blocked at air inlet or exit of power supply;
Coolant fan failed; radiator fins clogged with dirt.
Proper coolant flow of 0.7 gpm as measured by flow switch FS1 was not obtained
during up to 4 minutes of Priming. New installation can require additional Priming
cycle(s) to fill hoses with coolant; cycle power to restart Priming; Coolant hoses
or torch hoses reversed; Clogged coolant filter; Restriction in torch lead or head;
Wrong style consumables; broken or defective torch coolant tube/check valve; De-
fective or disconnected FS1 flow SW; Defective pump or bypass valve.
Low coolant level during cut, does not stop cut. Add coolant as required.
This is a warning, does not stop system operation. Coolant flow rate lower than ex-
pected. Can be caused by gas bubbles being introduced into the coolant or wrong or
mismatched or worn consumable parts; Failed seals in torch cartridge or torch body;
Clogged coolant filter; Restriction in torch lead or head; defective or disconnected FL1
flow sensor.
Coolant supply temperature exceeded 75 degrees Celsius (167 Fahrenheit) likely
cause ambient greater than 40 degrees Celsius (104 Fahrenheit); Reduce cutting
duty cycle; Reduce ambient temperature; Add separate coolant cooler.
CCM Status Code
CCM-Group-5 Gas Controller Communication Port
CCM to Gas Selection Console Fiber-optic control cable not connected, not
properly connected or cable defective. Gas Selection Console's power supply or
Control PCB defective. Defective CCM, replace.
Dirt on fiber ends or in connectors; blow out with clean dry air; Fiber not locked
into connector; Sharp bends in fiber; Fiber defective
Dirt on fiber ends or in connectors; blow out with clean dry air; Fiber not locked
into connector; Sharp bends in fiber; Fiber defective;
No information available; Contact customer service