Memory Fault; User Management Fault; Incompatible Units; Timing Fault - ESAB ROBUSTFEED EDGE Instruction Manual

Table of Contents

Advertisement

9   EVENT CODES

Memory fault

x19
This event code is displayed due to one of the following:
019 - Parameter memory read/write error.
019 - Log read/write error.
1.
Restart the system.
2.
Contact service technician.

User management fault

x20
This event code is displayed due to one of the following:
020 - No valid job available.
1.
Make sure that the predefined jobs are saved by admin.

Incompatible units

x25
This event code is displayed due to one of the following:
025 - System communication version mismatch warning/error.
025 - Power converter control module version not valid.
025 - Power converter control module power capacity unknown.
1.
Contact service technician.
2.
Make sure that the software version is the same for each connected node.
3.
Connect the correct wire feed unit and restart.

Timing fault

x26
This event code is displayed due to one of the following:
026 - Watchdog timeout.
026 - Process control error.
1.
Restart the system (recycle power).
2.
Acknowledge by pressing any buttons on the control panel.
3.
Contact service technician.

No coolant flow

x29
This event code is displayed due to one of the following:
429 - ELP off during welding.
1.
Check the coolant hose connections and acknowledge.

Gas pressure fault

x31
This event code is displayed due to one of the following:
631 - Gas input pressure warning/error.
1.
Check gas input pressure.
0463 786 001
- 59 -
© ESAB AB 2023

Advertisement