4.01 Power Supply Control Panel

AC Indicator
AC Power Lamp
Indicates unit has passed the input power tests and AC power is being supplied to the inverter modules via the input contactor
when the ON/OFF switch is in ON position.
TEMP Lamp: Normally OFF. Lamp will come ON when the internal temperature sensors detect temperatures above normal
limits. Let the unit cool before continuing operation.
GAS Lamp: Flashing during start up gas purge/pump priming, then steady whenever gas is flowing. Indicates adequate gas
pressure and coolant flow for operation.
DC Lamp: Indicates the power supply is generating output DC voltage.
A/
Status Indicator: Shows CCM code version on start up followed by the Current Control setting and system status.
Refer to Section 4.05 and Status Code Section for details.
Rear Panel AC Power Lamp
Indicates AC power is present inside the unit

4.02 System Operation

This section contains operating information which is specific to the power supply.
WARNING
Review the safety precautions in Section 1.
If the power supply cord has a plug or is not permanently connected to power, be sure the power to the
outlet is disconnected when inserting the plug into the outlet.
Disconnect primary power at the source before assembling or disassembling power supply, torch parts, or
torch and leads assemblies, or adding coolant.
It is not enough to simply move the ON/OFF switch on the unit to OFF position when cutting operations have
been completed. Always open the power supply disconnect switch five minutes after the last cut is made.
NOTE!
Prior to starting the system determine the process to be used. The process is determined by the type and
thickness of the metal to be cut. Select and install the required consumables, connect the required gasses
to the system.
0560956430

SECTION 4: OPERATION

Gas Indicator
Temp Indicator
Art # A-11541_AB
A/
Status Indicator
DC Indicator
A/
OPERATION