ESAB 100i Instruction Manual page 46

Plasma systems
Hide thumbs Also See for 100i:
Table of Contents

Advertisement

100i / 200i / 300i / 400i
Code
Message
1-1
Plasma Disabled
1-2
24 VDC fault
1-3
5 VDC fault
1-4
No gas process selected
Gas Selection Console is
1-5
locked
1-6
Gas not Purged
Gas Control Unit Ac-
2-1
knowledge error
Gas Control Unit Bus OFF
2-2
error
2-3
Reserved
3-1
CCM Acknowledge error
3-2
CCM Bus OFF error
3-3
Reserved
4-1
CCM Connection loss
4-2
CCM Timeout
46
Gas Selection Console Status Code Key
Group 1 - Gas Selection Console
Enable Plasma; Defective Gas Selection Console Power Supply (E-Stop relay)
Check /replace Gas Selection Console power supply fuse (F2); Replace Gas Selection
Console Power Supply; Replace Gas Selection Console control PCB
Check /replace Gas Selection Console power supply; Replace Gas Selection Console
control PCB
Select and send process from or CNC;
Process loading, wait until finished
Gas Control Unit fault prevented purge from occurring, see Gas Control Unit fault status
Group 2 - Gas Control Unit Communication Port *
Check Gas Selection Console to Gas Control Unit fiber optic cable and connections; Dirty
or defective fiber-optic;Gas Control Unit power supply, fuse or Control PCB. Gas Selec-
tion Console Control PCB
Check Gas Selection Console to Gas Control Unit fiber optic cable and connections; Dirty
or defective fiber-optic;Gas Control Unit power supply, fuse or Control PCB. Gas Selec-
tion Console Control PCB.
No information available; Contact customer service
Group 3 - CCM Communication Port *
Check Gas Selection Console to CCM fiber optic cable and connections; Dirty or defec-
tive fiber-optic; Replace Gas Selection Console Control PCB; Replace CCM.
Check Gas Selection Console to CCM fiber optic cable and connections; Dirty or defec-
tive fiber-optic; Replace Gas Selection Console Control PCB; Replace CCM.
No information available; Contact customer service
Group 4 - Gas Controller Status and Protocol Errors
Loss of communication with either Gas Control Unit or Gas Selection Console; check for
dirty or defective fiber optic to either Gas Control Unit or CCM; See Gas Control Unit and
CCM status codes
Loss of communication with either Gas Control Unit or Gas Selection Console, check for
dirty or defective fiber-optic to either Gas Control Unit or CCM. See Gas Control Unit and
CCM status codes.
OPERATION
Cause/Remedy
0560956430