Note: To maintain the EMI integrity and cooling of the server, install a new hot-swap redundant power
supply as soon as you remove the failing one or cover the other bay with a shield if you use one power supply
to provide power.
Removing a hot-swap power supply
To remove a hot-swap redundant power supply, do the following:
Watch the procedure. A video of the removing process is available at:
• Youtube:
https://youtu.be/bTi2WSjo03Y
• Youku:
http://v.youku.com/v_show/id_XMjYwODc0NzM3Ng==.html?&f=49135033&from=y1.2
1. Locate the failing power supply in the rear of your server and disconnect the power cord from the failing
hot-swap redundant power supply.
2. Press the release tab in the direction as shown and carefully pull the handle at the same time to slide the
failing hot-swap power supply out of the chassis.
Figure 51. Removing a hot-swap redundant power supply
3. If you are instructed to return the old hot-swap power supply, follow all packaging instructions and use
any packaging materials that are supplied to you for shipping.
Installing a hot-swap power supply
To install a hot-swap power supply, do the following:
Watch the procedure. A video of the installation process is available at:
• Youtube:
https://youtu.be/wYyE4WOer9E
• Youku:
http://v.youku.com/v_show/id_XMjYwODcxMDM0OA==.html?&f=49135033&from=y1.2