Daikin ACS320 Operation Manual page 109

Wall or cabinet mountable drive for controlling ac motors
Table of Contents

Advertisement

Table 74: Parameter Settings
MD4 Parameters
#
Name
9802
COMM PROT SEL
9901
LANGUAGE
9902
APPLIC MARCO
9905
MOTOR NOM VOLT
9906
MOTOR NOM CURR
9907
MOTOR NOM FREQ
9908
MOTOR NOM SPEED
9909
MOTOR NOM POWER
1001
EXT1 COMMANDS
1102
EXT1/EXT2 SEL
1103
REF1 SELECT
1104
REF1 MIN
1105
REF1 MAX
1106
REF2 SELECT
1201
CONST SPEED SEL
1601
RUN ENABLE
1604
FAULT RESET SEL
1607
PARAM SAVE
1608
START ENABLE 1
1611
PARAMETER VIEW
2101
START FUNCTION
2202
ACCELER TIME 1
2203
DECELER TIME 1
2605
U/F RATIO
3003
EXTERNAL FAULT 1
3009
BREAK POINT FREQ
3101
NUMBER TRIALS
3103
DELAY TIME
3104
AR OVERCURRENT
3404
OUTPUT1 DSP FORM
3405
OUTPUT1 UNIT
3415
SIGNAL3 PARAM
3418
OUTPUT3 DSP FORM
3421
OUTPUT3 MAX
4201
GAIN
4202
INTEGRATION TIME
5302
EFB STATION ID
5303
EFB BAUD RATE
5304
EFP PARITY
5306
EFB OK MESSAGES
5307
EFB CRC ERRORS
5308
EFB UART ERRORS
5309
EFB STATUS
8120
INTERLOCKS
1002
EXT2 COMMANDS
1301
MINIMUM AI1
1302
MAXIMUM AI1
1303
FILTER AI1
3502
INPUT SELECTION
4210
SET POINT SEL
1202
CONST SPEED 1
1401
RELAY OUTPUT 1
Vary depending on motor nameplate voltage and hp
These values vary depending on the application
Not important, will be HVAC default values
www .DaikinApplied .com
RoofPak & Self C
Maverick II
Unit
SAF, RAF & EAF
SAF
STD MODBUS
STD MODBUS
ENGLISH
ENGLISH
HVAC DEFAULT
HVAC DEFAULT HVAC DEFAULT
V
460
460
A
35
24
Hz
60
60
rpm
1775
1775
hp
30
20
COMM
COMM
EXT1
EXT1
COMM
COMM
Hz
0
0
Hz
60
60
KEYPAD
KEYPAD
NOT SEL
NOT SEL
COMM
COMM
COMM
COMM
DONE
DONE
COMM
COMM
LONG VIEW
LONG VIEW
SCAN START
SCAN START
s
60
60
s
60
60
LINEAR
LINEAR
DI 2(INV)
NOT SEL
Hz
45
45
5
5
s
3
3
ENABLE
ENABLE
DIRECT
DIRECT
%
Hz
AI 1
SPEED
+0 .0
DIRECT
44ma
1800 rpm
s
279
252
SAF=1,R/EAF=2
1
192
192
8 NONE 2
8 NONE 2
Usually a big number that continues to grow
0
0
Should be a small number that rarely grows unless a MicroTech III communication problem occurred
ON-LINE
ON-LINE
NOT SEL
NOT SEL
NOT SEL
NOT SEL
%
MicroTech III limits minimum speed to 20 hz
%
MicroTech III limits maximum speed to 60 hz
s
Hz
Maverick II
RPS / RDT / RCS
EAF
Condenser Fan
Condenser Fan
STD MODBUS
Not Selected
ENGLISH
ENGLISH
HVAC DEFAULT
HVAC DEFAULT
460
460
4
2 .6
60
60
1140
1142
3
1 .5
COMM
DI1
EXT1
EXT1
COMM
AI 1
0
24
60
60
KEYPAD
KEYPAD
NOT SEL
DI 3
COMM
DI 2
COMM
KEYPAD
DONE
DONE
COMM
DI 4
LONG VIEW
LONG VIEW
SCAN START
SCAN START
60
10
60
10
LINEAR
LINEAR
NOT SEL
NOT SEL
45
45
5
5
3
3
ENABLE
DISABLE
DIRECT
+0 .0
Hz
% SP
SPEED
AI 1
DIRECT
+0 .0
1800 rpm
10v
The Daikin software version [will grow over time]
228
106
2
1
192
96
8 NONE 2
Values Vary
0
0
ON-LINE
ON-LINE
NOT SEL
DI 4
NOT SEL
DI 1
10
50
0 .1
A I 1
AI 1
60
FAULT
109
RPE / RDE
RoofPak
Energy Rec Wheel
STD MODBUS
STD MODBUS
ENGLISH
ENGLISH
HVAC DEFAULT
460
460
11 .2
1 .1
60
60
1775
1775
5
1
COMM
COMM
EXT1
EXT1
COMM
COMM
0
0
60
60
KEYPAD
KEYPAD
NOT SEL
NOT SEL
COMM
COMM
COMM
COMM
DONE
DONE
NOT SEL
COMM
LONG VIEW
LONG VIEW
SCAN START
SCAN START
5
60
30
60
LINEAR
LINEAR
NOT SEL
NOT SEL
45
45
5
5
3
3
ENABLE
ENABLE
+0 .0
DIRECT
Hz
Hz
SPEED
SPEED
DIRECT
DIRECT
1800rpm
1800 rpm
103
202
4
3
192
192
8 NONE 2
8 NONE 2
0
0
ON-LINE
ON-LINE
NOT SEL
NOT SEL
NOT SEL
NOT SEL
MicroTech III limits minimum speed to 20 hz
MicroTech III limits maximum speed to 60 hz
OM 1190-1 • MD4 VFD
a
ppendIx
Maverick II & Rebel
Energy Rec Wheel
STD MODBUS
ENGLISH
HVAC DEFAULT
460
0 .5
60
1775
0 .2
COMM
EXT1
COMM
0
60
KEYPAD
NOT SEL
COMM
COMM
DONE
COMM
LONG VIEW
SCAN START
60
60
LINEAR
NOT SEL
45
5
3
ENABLE
DIRECT
Hz
SPEED
DIRECT
1800 rpm
204
3
192
8 NONE 2
0
ON-LINE
NOT SEL
NOT SEL