Command Codes For Retrieving Running Configuration - Moxa Technologies MiiNePort E1-SDK User Manual

Hide thumbs Also See for MiiNePort E1-SDK:
Table of Contents

Advertisement

MiiNePort E1/E2-SDK
Gateway
Command code: NG
Command parameters: MiiNePort's Gateway address.
Reply parameters: N/A
?SNG192.168.1.254
!SNG0
DNS
Command code: ND
Command parameters: The index (1,2) and DNS server address, separated by a semicolon (;).
Reply parameters: N/A
?SND1;192.168.1.123
!SND0

Command Codes for Retrieving Running Configuration

Device Name
Command code: BN
Command parameters: N/A
Reply parameters: MiiNePort's name.
?RBN
!RBN0MiiNePort_9527
IP configuration
Command code: NC
Command parameters: N/A
Reply parameters: MiiNePort's IP configuration index as follows.
0
Static
1
DHCP
2
DHCP/BOOTP
3
BOOTP
4
AutoIP
?RNC
!RNC00
IP address
Command code: NI
Command parameters: N/A
Reply parameters: MiiNePort's IP address.
?RNI
!RNI0192.168.127.254
Introduction to SCM (Serial Command Mode) Command Set
System sets Gateway as '192.168.1.254'.
MiiNePort reports command executed successfully.
System sets DNS1 as '192.168.1.123'.
MiiNePort reports command executed successfully.
System requests configured device name for this MiiNePort.
MiiNePort reports device name as 'MiiNePort_9527'.
System requests IP configuration for this MiiNePort.
MiiNePort reports IP configuration as 'Static'.
System requests IP address for this MiiNePort.
MiiNePort reports IP address as '192.168.127.254'.
A-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Miineport e2-sdk