Command Codes for Viewing the Status

Control Command Codes

PING
Command code: NP
Command parameters: Target host name or IP address.
Reply parameters: A single minus symbol indicates the target host did not reply in 1000 milliseconds.
Otherwise, one decimal number indicating the reply latency in milliseconds is returned.
?CNPwww.moxa.com
!CNP010
?CNP192.168.1.1
!CNP0-
Load Factory Default
Command code: LD
Note that this command is not applied to the configuration until you save and restart the MiiNePort.
Command parameters: '1' for "All setting", '0' for "Keep IP setting".
Reply parameters: N/A
?CLD0
!CLD0
Introduction to SCM (Serial Command Mode) Command Set
System requests to PING www.moxa.com.
Target host replies in 10 milliseconds.
System requests to PING 192.168.1.1.
Target host did not reply in 1000 milliseconds.
System requests to load factory default.
System loads factory default successfully.
A-7