MiiNePort E1/E2-SDK
Refer to Appendix A: Introduction to SCM (Serial Command Mode) Command Set for detailed
instructions on using SCM commands.

EXTrigger (External Trigger)

This function is for MiiNePort E1-SDK only.
The MiiNePort E1-SDK's EXTrigger has two functions: (1) Resetting the module to Moxa's default configuration,
and (2) Restarting the module. EXTrigger is designed to provide you with an easy network troubleshooting tool
that can be used without stopping the device's normal operation.
The Reset-to-Default function is enabled by default and cannot be disabled. This design prevents device
deadlock in the future if you or your customer forgets the password and is unable to access the console to
troubleshoot the device. To activate the EXTrigger's Reset to Default function, press the button inside the RJ45
jack for five seconds while your device and the MiiNePort E1-SDK is starting up.
The Restart function simply shuts down the module and then turns it back on. This does not affect any settings
in the module but is a commonly used method for initial troubleshooting. Simply hold the button for five
seconds at any time during device operation to restart the MiiNePort E1-SDK module.
NOTE
The Restart function of ExTrigger is disabled in Moxa's factory default settings.
Refer to the following table describing the LED interaction with EXTrigger.
EXTrigger
Restart
Fault/In Use
Blinking
LED Behavior
Duration
0.5 time/sec
5 sec
(Blinks amber
slowly)
Trigger Timing
Press the button anytime
during operation.
6-3
NetEZ Technologies
Note
When LED is Off (stops
blinking)
1. Function active