Serial Command Mode

SCM (Serial Command Mode) uses serial communication between the MiiNePort E1 and your device's main
system to configure the MiiNePort E1, usually during device operation. For more details about SCM commands,
refer to Chapter 7: NetEZ Technologies.
Port number
Setting
Port 1
SCM trigger mode
Setting
HW trigger
SW trigger
Bootup SW trigger
Break trigger
HW trigger: Entering the SCM mode by HW DIO and DIO trigger mode.
SW trigger: Entering the SCM mode by the continuous three characters. The default value is 0x58, 0x58, 0x58
Bootup SW trigger: Entering the SCM mode by the continuous three characters during the timeout period.
The default value is 0x58, 0x58, 0x58
Break trigger: Break signals are caused by sending continuous Spacing values (no Start or Stop bits). When
there is no electricity present on the data circuit, the line is considered to be sending a Break. The Break signal
must be of duration longer than the time it takes to send a complete byte plus Start, Stop, and Parity bits.
Factory Default
Port 1
Factory Default
SW trigger
5-13