Utility Console and Driver Installation
Adding an additional server
Modify the text file moxattyd.cf to add an additional server. User may use vi or any text editor to modify the
file. For more configuration information, refer to moxattyd.cf, which contains detailed descriptions of the
various configuration parameters.
Find the process ID (PID) of the moxattyd.
# ps -ef | grep moxattyd
Update the configuration of moxattyd.
# kill -USR1 [PID]
(e.g., if moxattyd PID = 404, kill -USR1 404)
This completes the process of adding an additional server.