SCOUT project download online process
1. Load the project data via SIMOTION SCOUT, menu Target system > Load > Load project
into target system..., into the working memory of the SIMOTION P320-4.
2. To transfer the data to the external storage medium, use the menu Target system > Copy
RAM to ROM in SIMOTION SCOUT.
The project data are transferred to the controller.
9.8.3.3

SIMOTION SCOUT - download of the project data (file structure)

The project data is saved by SIMOTION SCOUT in the form of the file structure in a file system
(e.g. a programming device with an engineering system).
The user copies this file structure to the external CFast card of the SIMOTION P320‑4.
This permits a series commissioning of SIMOTION programs.
Figure 9-4
Download of the project data process (file structure)
1. Save the data via SIMOTION SCOUT, menu Edit > Load to file system ... (option Save
normally), on the file system of your programming device.
2. Copy this data (file structure) to the external CFast card (drive D) of SIMOTION P320-4
(e.g. with USB memory stick and Windows Explorer).
SIMOTION P must be in the terminated state for this.
Note
Note the SIMOTION version
The SIMOTION version on the target device must exactly match the version of the device on
which the backup was created.