SIMATIC Industrial PC SIMATIC Rack PC 547B
SIMATIC
Industrial PC
SIMATIC Rack PC 547B
Operating Instructions
12/2007
A5E01127519-02
______________
Introduction
______________
Safety information
______________
Description
______________
Application planning
______________
Mounting
______________
Connecting
______________
Commissioning
______________
Integration
______________
Functions
Expansions and
______________
configuration
______________
Maintenance and service
______________
Troubleshooting/FAQs
______________
Specifications
______________
Dimension drawings
______________
Detailed descriptions
______________
Appendix
______________
ESD directives
List of
______________
abbreviations/acronyms
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC Rack PC 547B

  • Page 1 ______________ Introduction SIMATIC Industrial PC SIMATIC Rack PC 547B ______________ Safety information ______________ Description SIMATIC ______________ Application planning Industrial PC SIMATIC Rack PC 547B ______________ Mounting ______________ Connecting Operating Instructions ______________ Commissioning ______________ Integration ______________ Functions Expansions and ______________ configuration...
  • Page 2 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 3: Table Of Contents

    Connecting peripherals ........................29 Connecting the device to power....................30 Equipotential bonding ........................33 Commissioning ............................35 Requirements for commissioning....................35 Initial Commissioning - Initial Startup...................35 Windows XP, Vista Security Center.....................36 Notes on operation........................37 7.4.1 DVD burner ..........................37 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 4 11.2.10 Installing updates ........................86 11.2.10.1 Updating the operating system ....................86 11.2.10.2 Installing or updating application programs and drivers ............. 86 11.2.11 Data backup ..........................87 11.2.11.1 Creating an image........................87 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 5 Guidelines and declarations.......................109 Certificates and Approvals ......................110 Service and support ........................112 Retrofitting instructions ......................113 ESD directives ............................115 ESD guidelines ..........................115 List of abbreviations/acronyms ......................117 Abbreviations ..........................117 Glossary ..............................123 Index..............................133 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 6 Table of contents SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 7: Introduction

    Scope of validity of this document This documentation is valid for all variants of the SIMATIC Rack PC 547B and describes the device shipped as of December 2007. Position in the information landscape These operating instructions are available on the supplied "Documentation and Drivers"...
  • Page 8: Guideline To The Operating Instructions

    Design, function and features of the vital components, allocation of system resources and use of the BIOS Setup Appendix Guidelines and certifications, service and support, notes on retrofitting ESD directives General ESD guidelines. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 9: Safety Information

    Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. CAUTION If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 10 ● Always pull the mains connector and disconnect the battery before you install or remove modules which are sensitive to ESD. ● Handle modules fitted with ESDs by their edges only. ● Do not touch any wiring posts or conductors on modules containing ESDs. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 11: Description

    Description Overview The SIMATIC Rack PC 547B is a powerful industrial PC in 19" rack format design (4HE). It is perfectly suited for high-performance industrial PC applications. ● Maximum performance ● Attractive price Figure 3-1 SIMATIC Rack PC 547B SIMATIC Rack PC 547B...
  • Page 12: Areas Of Application

    ● Measurement, control and rule-based tasks ● Data acquisition and management The SIMATIC Rack PC 547B has CE certification for use in the industrial sector as well as in residential and commercial areas, and small businesses. In addition to the industrial applications, it can also be used in building services automation or in facilities open to the public.
  • Page 13: Function

    – Operating hours counter – Hard disk status – System status (Heart Beat) – Automatic logging of all messages to a log file – Option of remote monitoring of networked SIMATIC PCs SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 14: Features

    1 x PS/2 Audio Mic in, Line in, Line out Power supply 100 - 230 V AC, wide range; with short-term buffering against power failure: Max. 16 ms at 0.85 rated voltage SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 15 DVD-R/+R: Single Layer 16x, Dual Layer 7x DVD-RW/+RW 13x CD-ROM/CD-R 48x, CD-RW 40x Writing: DVD+R 18x, DVD+RW 8x, DVD-R 18x, DVD-RW 6x, DVD+R9 (DL) 8x, DVD-R DL 8x CD-R 48x, CD-RW 32x SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 16 Software tool for monitoring SIMATIC PCs both locally and remote: - Watchdog - Temperature - Fan speed - Hard disk monitoring (SMART, RAID Status) - System/Ethernet monitoring (heartbeat) SIMATIC PC Image Creator software Software tool for saving data locally SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 17: Design

    Installation option for 60 mm fan Blanking panel Option for installing a cover for external ports Expansion slots 4 x PCI, 2x PCIe x1, 1x PCIe x16 Connection elements Power supply connection SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 18: Operator Controls

    (press and hold more than 4 seconds) = hardware reset. CAUTION Data may be lost when the PC performs a hardware reset. WARNING The on/off button signal does not cut off power to the PC! SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 19: Connection Components

    COM 1 Serial port 1 (V.24), 9-pin D-sub connector (13) KEYBOARD Connection for a PS/2 keyboard (14) VGA connection (15) DVI-I DVI-I connection (16) Dual-head adapter Connector on dual-head graphics card (optional) SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 20 3.6 Design Power supply Position of the IEC power Description connector IEC connector for the AC power supply to the device. The maximum permitted power range is 120 to 240 V AC. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 21: Status Indicators

    No access HARDDISK Display for hard disk • access GREEN Access • Hibernate, switched off or unplugged POWER PC operating status • display YELLOW Windows standby • GREEN PC in operation • SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 22 Description 3.6 Design SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 23: Application Planning

    ● Verify that the shipment contains the complete unit and your separately ordered accessories. ● Please inform your local dealer of any disagreements or transport damages. ● Please inform Siemens AG by means of the enclosed SIMATIC IPC/PG quality control report form. SIMATIC Rack PC 547B...
  • Page 24 Serial number S VP ... Order no. 6AG4104-0 ... Microsoft Windows Product Key Ethernet address Device equipment You will find a list of device equipment on a label behind the front door. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 25: Ambient And Environmental Conditions

    WARNING If these conditions are not upheld while mounting the system, the approvals according to UL 60950, EN 60950 are forfeited and there is a danger of overheating and personal injury. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 26: Access Protection

    On/Off button (power button) are being used. Note In Windows, you have the option of setting the function of the On/Off button to meet your requirements. You can make these setting in the "Power Options" menu. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 27: Mounting

    Position of the mounting holes (1) for angle brackets or telescopic rails CAUTION The mounting screws of the telescopic rails may not protrude more than 5 mm into the enclosure. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 28 Rittal Type TE 7000.620, Rittal Type VR 3861.580, Rittal Type DK 7063.710. Please refer to the case manufacturer's instructions regarding device bases. CAUTION Risk of injury! It is not permitted to mount the device only on the 19" brackets of the front panel. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 29: Connecting

    - The computer must be turned off and the power supply connector should be plugged in. - During the measurement, all cables from the plant to the computer should be connected. - All other components in the plant must be active SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 30: Connecting The Device To Power

    UPS characteristics are described and classified in the standards EN 50091-3 or IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 31 Connect the power cord to the mains outlet and switch on the mains isolation switch (if this exists). The yellow power LED (standby) on the front panel of the PC lights up. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 32 Screw the power plug interlock (2) onto the power supply module. WARNING If the power plug is secured with a clamp, the power outlet must be freely accessible to allow the device to be easily removed from the mains. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 33: Equipotential Bonding

    (large surface, large-area contact) must be interconnected with the central grounding busbar of the cabinet or plant in which the PC is to be installed. The minimum conductor cross-section may not be less than 5 mm SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 34 Connecting 6.3 Equipotential bonding SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 35: Commissioning

    PC is automatically restarted and displays the user interface of the relevant operating system. From now on, after you switch on the PC, the user interface of the operating system is automatically opened when the startup routine is completed. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 36: Windows Xp, Vista Security Center

    You will also receive a warning if programs attempt to modify important Windows settings. Configure the Security Center according to your requirements. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 37: Notes On Operation

    The written data can only be verified by comparing these with the source. To be on the safe side, data should be verified after every burning session. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 38: Removable Hard Disks

    Information about the recovery of the RAID system is available in the next section. 1. Set the key switch to the "OPEN" position. 2. Lift up the folding handle of the hard disk cartridge. 3. Pull the hard disk cartridge out. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 39 Commissioning 7.4 Notes on operation Notes on operation NOTICE Always interlock the hard disk cartridge with the removable cartridge in order to ensure reliable operation of the device. Removable cartridge lock SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 40: 2Hdd System (Optional)

    NOTICE The drive letters for the partitions on both drives are assigned by the operating system used. You can change these in the Control Panel as required. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 41: Raid System

    Status Bootable Volume0 RAID1(Mirror) 149.1GB Rebuild Physical Disks: Port Drive Model Serial # Size Type/Status(Vol ID) ST3160815AS 5RA01YJT 149.1GB Member Disk(0) ST3160815AS 5RA01YHY 149.1GB Member Disk(0) Press <CTRL-I> to enter Configuration Utility... SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 42 The redundant system state RAID 1 is reached again only after synchronization is completed. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 43 The functioning hard drive is indicated in BIOS by its port number, or by the RAID software by its device port number. The functioning drive can be localized by means of the following table. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 44 Device Port 0 SATA1 (3) Side panel 1 Port 2 Device Port 2 SATA3 (4) Side panel 2 Please replace the faulty drive with a new one of the same type and capacity. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 45 "Operating System not found" will be displayed. Integrating a new hard drive Select the "Rescan for Plug and Play Devices" command to find and indicate the new HDD. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 46 The new hard disk is then assigned to a SATA port and can be included in the RAID array. The "Rebuild to this Hard drive" command initiates synchronization of the RAID1 system. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 47 In this case you need only stop the DiagMonitor SNMP Agent (SOL-Agent). ● In order to do so, select Start > Run and enter cmd in the field. ● Afterwards, enter Net stop snmp and confirm with the Enter key. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 48 Commissioning 7.4 Notes on operation NOTICE If you do not keep to the procedure described above, a correct RAID configuration cannot be guaranteed. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 49: Integration

    For this purpose you require the "SOFTNET S7" software package. Additional information You can find additional information in the catalog and to the online ordering system of Siemens A&D. Internet address: https://mall.ad.siemens.com SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 50 Integration 8.1 Integration SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 51: Functions

    Simultaneous installation and operation can result in errors because both programs access the same interfaces. A description of the drivers and SystemGuard is available on the enclosed "Documentation and Drivers" CD in the utilities directory. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 52: Temperature Monitoring/Display

    If the watchdog is activated and was not retriggered by the monitoring software within the selected time, the monitoring software is activated. You can find additional information on the supplied "Documentation and Drivers" CD in the utilities\sysguard directory. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 53: Fan Monitoring

    Utilities\Sysguard directory ● DiagMonitor can be ordered as an option. The DiagMonitor software CD contains the monitoring software, the software for the stations to be monitored, and a library for creating user-specific applications. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 54 Functions 9.5 Monitoring software SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 55: Expansions And Configuration

    No liability can be accepted for impairment of functions caused by the use of third-party devices or components. Observe the installation instructions for the components. UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 56 Expansions and configuration 10.1 Opening the device Opening the device Steps for opening the enclosure cover Remove the mounting screws (1). Lift up the lid from the back and remove it. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 57 Expansions and configuration 10.1 Opening the device Steps for opening the device front Tilt the front door (1) forward. Remove the fan cover (2). SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 58: Memory Expansion

    You will find notes on the allocated resources in the motherboard technical manual D2156-S21 on the supplied "Documentation and Drivers" CD and in the section Detailed descriptions > System resources. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 59: Installing An Expansion Module

    With short expansion modules, you can remove the locking screw from the bracket and screw it into the hole on the opposite side. Close the device. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 60: Installing Drives

    Drive bay module Item Description Horizontal drive bay Vertical drive bay 3.5" floppy desk drive (FD) 5.25" mounting bays for DVD/CD or hard drives in removable cartridges SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 61: Installing And Removing A Disk Drive Or Removable Rack

    Lift the drive bay module (1) out of the device until you can access the cables of the floppy disk drive. Disconnect these cables. Remove the drive bay completely from the device. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 62 Mount the disk drive into the drive bay using four screws. Insert the drive bay module again. Connect the power and data cables to the disk drive. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 63: Installing And Removing A Hard Disk

    (1) or (2). Removing drives How to remove a drive Disconnect the power and data cables from the drive. Remove the four screws (1) or (2) and take the drive out of the housing. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 64 Expansions and configuration 10.4 Installing drives SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 65: Maintenance And Service

    No liability can be accepted for impairment of functions caused by the use of third-party devices or components. Tools All mechanical installation tasks on the device can be carried out with Torx T10 and Torx T20 screwdrivers as well as a side-cutter. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 66: Replacing Filters

    Replacing filters Note Filter meshes are available under the following order numbers: A5E00246975 How to replace the filter 1. Tilt the front door (1) downwards. 2. Remove filter cover (2) and remove filter. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 67: Removing The Device Fan

    1. Tilt the front door (1) downwards. 2. Lift off the fan cover (2). 3. Open the device cover. 4. Unplug the fan connector from the motherboard. 5. Remove all fan screws. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 68 11.1 Removing and installing hardware components Installing the fan NOTICE Always install a fan of the same type! CAUTION Ensure that the arrow on the fan points away from the fan bracket. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 69: Replacing The Backup Battery

    Risk of damage! The lithium battery may only be replaced with an identical battery or with a type recommended by the manufacturer. Information about original spare parts for SIMATIC PCs is available at http://www.siemens.com/asis Disposal CAUTION Depleted batteries must be disposed of in accordance with local regulations.
  • Page 70: Removing The Power Supply Module

    Lift the power supply module out of the enclosure until you can access the power cable of the floppy disk drive. Disconnect this power cable from the floppy disk drive. Remove the screws (2) on the steel bracket. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 71: Removing The Motherboard

    Remove all modules from their slots. Disconnect all cables from the motherboard, noting down their positions while doing so. Remove ten screws from the motherboard. A replacement motherboard is supplied without processor and memory modules. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 72: Processor Replacement

    How to remove the processor 1. Unhook the fan holder on the heat sink and pull off towards the front. 2. Disconnect the processor fan connector. 3. Loosen the four screws and remove the heat sink. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 73 Operating a processor at a frequency higher than it specified speed can result in damage to the device and the loss of data. Only certified and approved processors can be used with the supplied motherboard. For more information contact your local Siemens representative. http://www.siemens.com/automation/partner SIMATIC Rack PC 547B...
  • Page 74: Reinstalling The Software

    CD2 or DVD. Documentation and Drivers CD: Contains the documentation and the hardware drivers. Restore DVD: Contains a hard disk image file with the original factory software (operating system with installed hardware drivers). SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 75: Restoring The Factory State Of The Software Using The Restore Dvd

    All existing data, programs, user settings and authorizations or license keyswill be deleted from the hard disk and therefore lost. For information on the functions, refer to the README.TXT file on the Restore DVD. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 76: Installing Windows

    2. Select the CD/DVD drive. Follow the instructions on the screen until the "Siemens SIMATIC Recovery" window is displayed. When using the recovery function with Vista, confirm that you want to boot from CD or DVD as soon as you restart.
  • Page 77: Setting Up Partitions For Windows 2000, Xp, Server 2003 Operating Systems

    1. Boot from the Recovery CD and then follow the on-screen instructions until the Recovery functions window is displayed. 2. Start the DiskPart tool in the "Siemens SIMATIC Recovery" window. Enter the following commands in the displayed command interface: List disk Displays all available hard disks.
  • Page 78 File system = Specifies the type of file system. Valid values: FAT, FAT32, NTFS. NTFS is the factory setting for all Windows operating systems. Example for the primary hard disk in the system: format C:/FS:NTFS format /? Shows all parameters of the command. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 79: Installing Microsoft Windows Operating Systems

    This CD contains encrypted data that can only be transferred to this system. 1. Boot from the Recovery CD and then follow the on-screen instructions until the Recovery functions window is displayed. 2. Select "Recovery Windows ..." in the "Siemens SIMATIC Recovery" window. 3. Follow the instructions on the screen. Note...
  • Page 80: Setting Up The Language Selection For Windows 2000 Mui

    Start > Settings > Control Panel > Regional Options>General tab, Menus and dialogs field and Language settings for the system field and the Input language field in the Input Locales tab. If you want to install additional languages, start the MUISETUP.EXE program from the recovery CD2 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 81: Language Selection On Windows Xp Professional And Windows Server 2003

    For the Date, Time, Language, and Regional Options, set the default as non-Unicode programs under Advanced in addition to the language for menus and dialogs If you want to install additional languages, start the MUISETUP.EXE program from the recovery CD 2. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 82: Recovery Of Windows Vista

    In the next dialog box, you can set up the hard disk according to your requirements and add controllers that are not yet known to the system. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 83 The first partition should be at least 25 GB. The operating system must be installed on this partition. You can use the rest of the hard disk as a data partition. Both partitions must be installed as the NTFS file system. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 84 You will find the necessary files on the recovery DVD in the "Languagepacks" folder. Start > Control Panel > Clock, Language, and Region > Change display language > Regional and Language options > Keyboards and Languages SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 85: Installing Drivers And Software

    Windows operating system. To display the list completely, you may need to scroll down with the arrow keys. 11.2.9 Installing burner/DVD software Information about installation of the burner / DVD software is available on the supplied CD. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 86: Installing Updates

    NOTICE Before you install new drivers or operating system updates for Windows versions, set the default language to US English in the regional settings for menus and dialogs. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 87: Data Backup

    This tool provides comfortable and efficient functions for backup and restoring the full content of Compact Flash cards, of HDDs and of individual partitions (images.) The software can be ordered from the Siemens A&D online ordering system. For detailed information about SIMATIC PC Image Creator, please refer to the corresponding product documentation.
  • Page 88 Maintenance and service 11.2 Reinstalling the software SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 89: Troubleshooting/Faqs

    2. Set the time and date in the setup menu. Although the BIOS setting is The backup battery is dead. In this case, please contact your technical support team. OK, the time and data are still wrong. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 90 "Boot device not found" is in the boot priority in the of the BIOS setup or permit boot device in the boot priority displayed BIOS setup or is not permitted as boot device SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 91: Problems When Using Modules Of Third-Party Manufacturers

    Connector assignments deviate, • occurs, the third-party module was the cause of the No "Reset Configuration" • fault. Replace this module with a Siemens module executed in BIOS SETUP. or contact the module supplier. Force a "Reset Configuration" using the BIOS •...
  • Page 92 Troubleshooting/FAQs 12.2 Problems when using modules of third-party manufacturers SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 93: Specifications

    Pollution gas EN 60721-3-3;1995 class 3C2 Sulphur dioxide and hydrogen sulphide class 3C3 Security Protection class Protection class I compliant with IEC 61140 Safety regulations EN60950-1, UL60950, CSA C22.2 No 60950-00 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 94 (2.4 GHZ, 1066 MHz FSB, 4 MB L2C, EM64T, VT) Intel® Core™ 2 Duo E4300 (1.8 GHZ, 800 MHz FSB, 2 MB L2C, EM64T) Intel® Celeron® 440 (2.0 GHz, 800 MHz FSB, 512 KB L2C) SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 95 Graphics controller Intel® GMA950 graphics controller, chipset integrated 2-D and 3-D engine, Up to 2048 x 1536 at 75 Hz Graphics memory Dynamic Video Memory Technology (uses up to 224 MB of RAM) SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 96 When using a hard disk in a removable cartridge, the device should generally be free of mechanical disturbances. When using a DVD burner, the device should generally be free of mechanical disturbances during burning. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 97: Power Requirements Of Components (Maximum Values)

    The accumulated power of the +5 V and + 3.3 V supply may not exceed 190 W The maximum inrush current is for: 110 V AC: 25 A, 5 ms 230 V AC: 30 A, 5 ms SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 98: Technical Data Of The Telescopic Rails

    At least 470 mm Rail thickness Maximum 9.7 mm Mounting screws M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 99: Dimension Drawings

    Dimension drawings 14.1 Dimensional drawing of the device Figure 14-1 Dimension drawing of the device SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 100: Dimensional Drawing For The Use Of Telescopic Rails

    Dimension drawings 14.2 Dimensional drawing for the use of telescopic rails 14.2 Dimensional drawing for the use of telescopic rails Figure 14-2 Dimension drawing for the use of telescopic rails SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 101: Dimensional Drawings For The Installation Of Expansion Modules

    Dimension drawings 14.3 Dimensional drawings for the installation of expansion modules 14.3 Dimensional drawings for the installation of expansion modules Figure 14-3 Long PCI module, PCIe module SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 102 Dimension drawings 14.3 Dimensional drawings for the installation of expansion modules SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 103: Detailed Descriptions

    Windows 2000, XP or Server 2003 Start > Run : In the Open box, enter "msinfo32" and confirm with OK Vista Start > Enter "cmd" in the search function , then enter "msinfo32" in the input box SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 104: Interrupt Assignments

    Detailed descriptions 15.3 Interrupt assignments 15.3 Interrupt assignments The functions are assigned different interrupts, depending on the operating system. A distinction is made between the PIC and APIC modes. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 105 Detailed descriptions 15.3 Interrupt assignments SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 106 1. Disable serial port 2, so that IRQ3 becomes free Advanced > PCI Configuration > Serial 2: disabled 2. Assign IRQ 3 to slot 4 Advanced > PCI Configuration > IRQ 3 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 107: Bios Setup

    Pay special attention to the correct settings in the "Power" tab. All menu items are set to "Disabled" by default. The operating system functions "Save to RAM" (standby) and "Save to Disk" (hibernate) are not approved for the Rack PC. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 108 Detailed descriptions 15.4 BIOS Setup SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 109: Appendix

    EC directives stated above. Your local sales representative can provide these on request. Observing the installation guidelines The installation guidelines and safety instructions specified in this documentation must be observed for commissioning and operation. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 110: Certificates And Approvals

    Peripheral devices may only be connected via shielded cables. Certificates and Approvals DIN ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets DIN ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 111 This Class A digital apparatus complies with Canadian ICES-003. Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. AUSTRALIA This product meets the requirements of the AS/NZS CISPR 22 Standard. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 112: Service And Support

    Easy shopping with the A&D Mall Catalog & online ordering system http://www.siemens.com/automation/mall Training All the training options are listed at: http://www.siemens.com/sitrain Find a contact at: Phone: +49(911) 895-3200 Technical support Tel +49 180 5050 222 Fax +49 180 5050 223 http://www.siemens.com/automation/service...
  • Page 113: Retrofitting Instructions

    A removable cartridge with hard disk can be installed instead of DVD drive(s). Devices equipped with removable cartridges may not to be exposed to shock during operation as described by DIN IEC 600682. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 114 Appendix A.4 Retrofitting instructions SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 115: Esd Directives

    The electrostatic discharge current may lead to latent failure of a module, that is, this damage may not be significant immediately, but in operation may cause malfunction. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 116 PCB traces. In this way, the discharged energy can not affect the sensitive devices. Discharge your body before you start taking any measurements on a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 117: List Of Abbreviations/Acronyms

    EC directives Compact Flash Color Graphics Adapter Standard monitor interface Clock pulse Clock signal for controllers CMOS Complementary Metal Oxide Complementary metal oxide semiconductors Semiconductors Certificate of authentication Microsoft Windows Product Key SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 118 Enhanced Parallel Port Bi-directional Centronics interface Escape character Control character Enhanced Write Filter Frequently Asked Questions FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table Floppy disk Disk drive, 3.5" SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 119 Mean Time Between Failures Multilanguage User Interface Language localization in Windows Not Applicable NAMUR Normenarbeitsgemeinschaft für Mess- und Regelungstechnik in der chemischen Industrie (standardization body for instrumentation and control technology in the chemicals industry) SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 120 Hard disk error diagnostics program Technology Short Message Service Short message via telecommunication network SNMP Simple Network Management Protocol Network protocol SO-DIMM Small Outline Dual Inline Memory Module SafeCard on Motherboard (SOM) SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 121 Loss-free file format for audio data Watchdog Program monitoring with error detection and alarming. WLAN Wireless LAN LWireless local area network World Wide Web Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 122 List of abbreviations/acronyms C.1 Abbreviations SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 123: Glossary

    Start or restart of the computer. During booting the operating system is transferred from the system data medium to the work memory. Cache High-speed access buffer for interim storage (buffering) of requested data. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 124 . This is done either by copying the configuration files supplied with the module or by manual configuration using the configuration utility. Controller Integrated hardware and software controllers that control the functions of certain internal or peripheral devices (for example, the keyboard controller). SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 125 Configurable write filter that allows you, for example, to boot Windows XP Embedded from write-protected media (such as CD-ROM), to write protect individual partitions and adapt the performance of the file system to your needs (when using Compact Flash cards). SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 126 Image This refers to the image, for example, of hard disk partitions saved to a file in order to restore them when necessary. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 127 Legacy USB support Support of USB devices (e.g. mouse, keyboard) on the USB ports without driver. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 128 Generic term which describes all functions for controlling and monitoring user program execution, distribution of system resources to the user programs and the operating mode in cooperation with the hardware (for example Windows XP Professional). SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 129 (for example monitors, modems or printers). The user can plug in a peripheral and "play" it at once without manually configuring the system. A Plug&Play PC requires both a BIOS that supports Plug&Play and a Plug&Play expansion card. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 130 The Restore DVD is used to restore the system partition or the entire hard disk to factory state if the system has crashed. The bootable DVD contains all the necessary image files. You can also create a boot disk allowing restoration via the network. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 131 Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 132 Wireless LAN is a local network that transmits data via radio waves, infrared light or another wireless technology. Wireless LAN is mainly used for mobile computer applications in office or factory environments. SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 133: Index

    Front view, 17 Data backup, 87 Degree of protection, 93 Device configuration, 107 Device fan, 67 Graphics, 95 Disk drives, 15 Guidelines Drive bay module, 60 ESD guidelines, 115 Drive bay plate, 63 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 134 Overview of functions, 15 Power supply, 14, 20 Status displays, 21 Power supply Watchdog, 15, 52 Connecting, 30 Monitoring software, 53 Power supply Motherboard, 103 AC supply voltage, 97 Motherboard Power Supply SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 135 Serial number, 24 Shipping, 23 Simatic S7, 49 Slot cover, 59 Slots, 14 SOFTNET S7, 49 Specifications, 93 Status displays, 21, 96 Supply voltage, 31, 93 System partition, 75 System resources, 103 SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...
  • Page 136 Index SIMATIC Rack PC 547B Operating Instructions, 12/2007, A5E01127519-02...