Advertisement

Quick Links

SIMATIC Industrial PC SIMATIC Box PC 827B
SIMATIC
Industrial PC
SIMATIC Box PC 827B
Getting Started
07/2008
A5E01127540-02
______________
Introduction
______________
Description
______________
Application Planning
______________
Mounting
______________
Connecting
______________
Commissioning
______________
Troubleshooting
______________
Dimensional drawings
______________
Appendix
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC Box PC 827B

  • Page 1 ______________ Introduction SIMATIC Industrial PC SIMATIC Box PC 827B ______________ Description ______________ Application Planning SIMATIC ______________ Mounting Industrial PC SIMATIC Box PC 827B ______________ Connecting ______________ Commissioning Getting Started ______________ Troubleshooting ______________ Dimensional drawings ______________ Appendix 07/2008 A5E01127540-02...
  • Page 2 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 3: Table Of Contents

    Commissioning ............................31 Requirements for commissioning....................31 Basic commissioning - initial startup....................31 Reinstalling the software......................32 6.3.1 General installation procedure .....................32 Troubleshooting ............................33 General problems ........................33 Dimensional drawings..........................35 Dimensional Drawing of the Device .....................35 SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 4 Table of contents Appendix..............................39 Guidelines and declarations......................39 Certificates and approvals......................41 Service and support ........................43 SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 5: Introduction

    SIMATIC Box PC 827B. Scope of validity of this document This documentation is valid for all delivery variants of the SIMATIC Box PC 827B and describes the delivery status as of July 2008. Operating instructions SIMATIC Box PC 827B The operating instructions are available on the supplied "Documentation and Drivers"...
  • Page 6 Introduction SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 7: Description

    7 segment display and two LEDs for POST code (optional) Slot for CompactFlash card Power supply fan On / Off switch IEC connector for AC power supply or connection for 24 V DC power supply Battery compartment SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 8 Rating label with serial number Device fan Side view (drive side) Input data of the power supply Drive bay module for hard disks and DVD burner Bottom Connection for equipotential bonding SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 9: Operator Controls

    WARNING The On/Off switch does not disconnect the device from the supply system. NOTICE Close the operating system before shutting down the device with the on/off switch, otherwise data may be lost. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 10: Connection Elements

    CP 1616 onboard interface, three RJ45 connectors (optional product characteristic) The interfaces available on the device have been numbered to uniquely distinguish between them. This may deviate from the operating system numbering. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 11 AC power supply Position of the IEC power connector Description IEC power connector to AC power supply of the device. The maximum permitted power range is 100 V AC to 240 V AC. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 12 Description 2.3 Connection elements DC power supply Position of the DC power connector Description Plug connector for DC power supply of the device + (24 V DC) - (ground) PE (ground terminal) SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 13: Status Displays

    The two "virtual" CP 1616 LEDs are only visible in the SIMATIC software and can be read via SNMP. PROFINET Virtual LEDs CP is active STOP CP is in the stop state Flashes The states "flashes slowly" or "flashes rapidly" do not exist. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 14 LED H2 Power on Orange Orange (= status display test) BIOS self test xxh (see BIOS postcode) BIOS self test completed Operating system is running or application-driven Operating system is shut down SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 15: Application Planning

    ● Check the delivery unit for any visible transport damage. ● Verify that the shipment contains the complete unit and your separately ordered accessories. Please inform your local dealer of any disagreements or transport damage. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 16: Device Identification Data

    The Product Key is always required to reinstall the operating system. COA label Serial number: S VP ... Order No. 6ES ... Microsoft Windows Product Key Ethernet address 1 Ethernet address 2 CP 1616 onboard layer 2 SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 17: Ambient And Environmental Conditions

    ● The connected or built-in peripherals should not introduce a counter emf in excess of 0.5 V into the device. WARNING Failure to adhere to these conditions when mounting the system voids the approvals based on UL 60950-1, UL 508 and EN 60950-1! SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 18: Permitted Mounting Positions

    3.5 Permitted mounting positions Permitted mounting positions PC mounting positions according to UL60950-1/UL508/EN60950-1/CSA22.2 No. 60950-1 An inclination of ± 20° is permitted for all approved mounting positions. Position 1 (preferred) Position 2 Position 3 (desktop) SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 19 Mounting positions 4 and 5 are also permitted for the Information Technology Equipment area when the device is mounted in an enclosure that fulfills the requirements stipulated by sections 4.6 and 4.7.3 of IEC/UL/EN/DIN EN 60950-1. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 20 Application Planning 3.5 Permitted mounting positions SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 21: Mounting

    The correct use of the device has to be verified with a function test on the system. This test can detect programming, configuration and wiring errors. The test results have to be documented and if necessary inserted into the relevant inputs. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 22: Installation Of The Device With Mounting Brackets

    WARNING Ensure that the wall is capable of carrying at least four times the total weight of the device (including the brackets and expansion modules). The total weight is approx. 9 kg. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 23: Installation Of The Device With The Vertical Mounting Kit

    With the available optional vertical mounting kit you have the possibility to implement a place saving installation. Mounting the vertical mounting plate onto the device Remove the equipotential bonding screw (1) from the device and attach it with the vertical mounting plate (2). SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 24 4.3 Installation of the device with the vertical mounting kit Attach the vertical mounting plate with four M4 screws and three M3 screws to the device Note Following instructions in the "Permitted mounting positions" section. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 25: Connecting

    • The computer in question must be turned off and the power supply connector should be plugged in. • During the measurement, all cables from the plant to the computer should be connected. • All other components in the plant must be active. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 26: Connecting The 120 V / 230 V Ac Power Supply

    UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 27 (Off) when you plug in the power cord in order to avoid unintentional startup of the device. Connect the IEC connector Connecting the power cord to the power socket Fasten the cable with the supplied power plug latch, if necessary. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 28: Connecting The (24 V) Dc Power Supply

    24 V power supply. Switch off the 24 V DC power source. Insert the DC power plug. (1) 24 V DC (2) ground (3) protective conductor SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 29: Connecting Equipotential Bonding

    Connect the equipotential bonding terminal on the device (large surface, large-area contact) to the central grounding busbar of the cabinet in which the device is installed. The minimum cross-section is 5 mm SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 30 Connecting 5.4 Connecting equipotential bonding SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 31: Commissioning

    Authentication", in the "Product Key" line. NOTICE The PC may not be switched off when you run setup. Do not change the default BIOS settings, otherwise the operating system setup may become corrupted. 4. Automatic restart SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 32: Reinstalling The Software

    Contains the tools for setting up hard disk drives and the operating system. Documentation and Drivers CD: Contains the documentation and the hardware drivers. Restore DVD: Contains a hard disk image file with the original software (operating system with installed hardware drivers). SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 33: Troubleshooting

    Should the mouse cursor still not be visible on-screen after completing these checks and measures, contact technical support. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 34 2. Insert a pointed object, a pin for example, or an opened paper clip application. into the emergency extraction opening of the drive. Apply slight pressure to the contact until the front loader opens. 3. Pull the loader further out. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 35: Dimensional Drawings

    Dimensional drawings Dimensional Drawing of the Device Figure 8-1 Dimensional drawing for mounting with angle bracket SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 36 Dimensional drawings 8.1 Dimensional Drawing of the Device Figure 8-2 Dimensional drawing for mounting without angle bracket NOTICE When mounting devices with optical drives or WinAC backup batteries change the fitting depth. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 37 Dimensional drawings 8.1 Dimensional Drawing of the Device Figure 8-3 Dimensional drawings for vertical mounting (model without DVD burner and without WinAC backup battery) SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 38 Dimensional drawings 8.1 Dimensional Drawing of the Device NOTICE When mounting devices with optical drives or WinAC backup batteries change the fitting depth. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 39: Appendix

    EC directives stated above. Your sales representative can provide these on request. Note the installation guidelines The installation guidelines and safety instructions given in this documentation have to be noted during commissioning and operation. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 40 Index Connecting peripherals Noise immunity requirements to EN 61000-6-2 are met if connected peripherals are suitable for industrial applications. Peripheral devices are only be connected via shielded cables. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 41: Certificates And Approvals

    Index Certificates and approvals ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets DIN ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 42 This Class A digital apparatus complies with Canadian ICES-003. Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. AUSTRALIA This product meets the requirements of the AS/NZS CISPR22. SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...
  • Page 43: Service And Support

    Easy Shopping at the Mall Catalog & online ordering system http://www.siemens.com/automation/mall Training All the training options are listed at: http://www.siemens.com/sitrain Find a contact at: Phone: +49(911) 895-3200 Technical support Tel +49 180 5050 222 Fax +49 180 5050 223 http://www.siemens.com/automation/service...
  • Page 44 Index SIMATIC Box PC 827B Getting Started, 07/2008, A5E01127540-02...