Connection

5.6 Connecting Ethernet

When installing the indoor bus cable, you should also remember the following boundary
conditions (d
Table 5-2
Features
Bending radius for a single bend
Bend radius for multiple bends
Permissible temperature range for installation
Temperature range for storage and stationary op‐
eration
Note
The length codes for the pre-assembled cables can be found on the website
www.siemens.com/simotion (www.siemens.com/simotion).
5.6
Connecting Ethernet
Procedure
Plug the LAN cable into the Ethernet interface of the SIMOTION P320‑4. You must hear the
connection engage properly.
Cables
Standard shielded twisted pair cables are used for the networking in this case.
The following connection cables are recommended:
● SIMATIC NET, ind. Ethernet TP XP CORD RJ45/RJ45, TP CORD assembled with 2 RJ45
connectors, send and receive cables crossed (cross-over)
Order no.: 6XV1850-2H*)
● SIMATIC NET, ind. Ethernet TP CORD RJ45/RJ45, TP CORD assembled with 2 RJ45
connectors
Order no.: 6XV1850-2G*)
*) Length code
58
= outer diameter of the cable):
A
Boundary conditions for indoor routing of bus cable
Dimensions
E50
0.5 m
H10
1 m
H20
2 m
H60
6 m
N10
10 m
General conditions
≥ 80 mm (10 × d
)
A
≥160 mm (20 × d
)
A
- 5° C to + 50° C
- 30° C to + 65° C
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 01/2015