Siemens SIMOTION P320-4 E Commissioning And Hardware Installation Manual page 14

Hide thumbs Also See for SIMOTION P320-4 E:
Table of Contents

Advertisement

Safety notes
1.1 Fundamental safety instructions
When assessing the machine's risk in accordance with the respective local regulations (e.g.
EC Machinery Directive), the machine manufacturer must take into account the following
residual risks emanating from the controller and drive components of a drive system:
1. Unintentional movements of driven machine components during commissioning, operation,
maintenance, and repairs caused by, for example:
– Hardware defects and/or software errors in the sensors, controllers, actuators, and
– Response times of the controller and drive
– Operating and/or ambient conditions outside of the specification
– Condensation / conductive contamination
– Parameterization, programming, cabling, and installation errors
– Use of radio devices / cellular phones in the immediate vicinity of the controller
– External influences / damage
2. In the event of a fault, exceptionally high temperatures, including an open fire, as well as
emissions of light, noise, particles, gases, etc. can occur inside and outside the inverter,
for example:
– Component malfunctions
– Software errors
– Operating and/or ambient conditions outside of the specification
– External influences / damage
Inverters of the Open Type / IP20 degree of protection must be installed in a metal control
cabinet (or protected by another equivalent measure) such that the contact with fire inside
and outside the inverter is not possible.
3. Hazardous touch voltages caused by, for example:
– Component malfunctions
– Influence of electrostatic charging
– Induction of voltages in moving motors
– Operating and/or ambient conditions outside of the specification
– Condensation / conductive contamination
– External influences / damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk
to people with a pacemaker, implants or metal replacement joints, etc. if they are too close.
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly.
14
connection technology
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 01/2015

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion p320-4 s

Table of Contents