9.10

Deleting user data on the CFast card

Requirement
You can delete the user data with SIMOTION SCOUT. The SIMOTION P320-4 must be online.
The user data in the RAM, the persistent data in the SRAM (except for the communication
configuration), and the user data on the CFast card are deleted. You can thus continue to
access the SIMOTION P320-4 with your PG/PC.
Procedure
To delete the user data:
1. In SIMOTION SCOUT, open the project you want to edit.
2. Go online with SIMOTION P320-4.
3. Select Target system > Delete user data on card....
The data is deleted.
9.11

Switching off

Windows
To ensure the safe operation of SIMOTION P320-4, Windows must be properly shut down
before the SIMOTION P320-4 is switched off.
Note
Use the Windows start menu to shut down the Windows system properly: Start > Shut down.
If Windows is not shut down properly, the Windows installation may become damaged to the
extent that it may no longer be possible to run SIMOTION P320-4.
Note
Applies only for SIMOTION P320-4 E
SIMOTION P320-4 E is delivered with deactivated EWF (Enhanced Write Filter).
After commissioning the SIMOTION P320-4 E, activate the EWF for drive C, which ensures:
● An extended service life for the CFast card
● No data loss when switching the device off via the line side switch or through disconnection
from the power supply
SIMOTION P320-4 E / P320-4 S