Delete Sram Via Simotion P State - Button Restart (Del. Sram) - Siemens SIMOTION P320-4 E Commissioning And Hardware Installation Manual

Hide thumbs Also See for SIMOTION P320-4 E:
Table of Contents

Advertisement

If a backup of the retain data (PMEMORY.XML) exists, this data will be accepted after the
overall reset. Thus, the user can perform an overall reset to force the saved retain data to be
restored.
Figure 9-14
9.8.5.4

Delete SRAM via SIMOTION P State - button Restart (Del. SRAM)

SIMOTION P320-4 will be restarted and the data in the SRAM will also be deleted.
The loading of a backup allows the SIMOTION P320-4 to be returned to a defined initial state.
The backed up program variables and retain variables and thus the encoder values, homing
data will be restored.
Figure 9-15
If the SIMOTION SCOUT function Target system > Copy RAM to ROM was called previously,
the saved project will be reloaded.
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 01/2015
Restore retain data
Delete SRAM - Restart (Del. SRAM)
Commissioning (software)
9.8 Data storage concept
109