5.2.2

GA 5000EAEC MODE OF OPERATION

Pneumatic diagram:
SA = Shaping air
AA = Atomizing air
CA = Control air
M =
Product
Open:
First, the external air valve, which enables the shaping and atomizing air, is opened.
The diaphragm in the drive is then charged with control air and moves toward the rear,
opening the product valve. In this position, the pressurized coating product is applied to
the work piece.
Close:
If the control air is deactivated, the product valve closes due to the pressure spring.
The air valve is then closed externally.
Additional functions:
The shaping air pressure and the atomizing air pressure are set externally via separate
pressure regulators. Both air fl ows are supplied separately, which allows them to be set
separately.
ORDER NUMBER DOC2360924
M
CA
SA
AA
B_06008
GA 5000EA
Nozzle
SA
AA
26