Connecting Ga 5000Eaic - WAGNER GA 5000EAIC Translation Of The Original Operating Manual

Electrostatic air spray gun
Table of Contents

Advertisement

VERSION 09/2016
OPERATING MANUAL
6.5.2

CONNECTING GA 5000EAIC

Incorrect installation/operation!
Risk of injury and damage to the device.
Procedure:
1. Place the control unit outside the explosion zone.
2. Mount spray gun to an grounded gun mounting.
3. Connect the grounding cable to the control unit and the signal ground.
4. Connect the gun connection cable to the control unit.
5. Connect the control unit to the higher-level controller (if available).
6. Connect the air hoses to the control unit and the spray gun in accordance with the
fi gure below.
7. Set all airs to "0" using the regulator on the front side of the control unit!
8. Connect the control unit to the compressed air supply.
9. Connect the spray gun to the product supply system.
10. Connect the control unit to the power supply.
EPG 5000
1 for the product supply system
2 Shaping air and atomizing air hose
3 Control air hose
ORDER NUMBER DOC2360924
WARNING
When commissioning and for all work, read and follow the
operating manual and safety regulations for the additionally
required system components.
GA 5000
4
Main Switch
Hauptschalter
I
IN
CAN Bus OUT
Data and Interlock
0
Daten und Verriegelung
Prim. Fuse
CAN
Sicherung
Address
1.0 AT
Mains power IN
Netz Eingang
Spraygun
Interface
Sprühpistole
Schnittstelle
Umax. = 20Vpp
Imax. = 1.0A
Service
Port
4 Gun cable
5 for the compressed air supply
6 Control cable
2
3
Air input
Atomizing air
II (2) G
0102
Lufteingang
Zerstäuberluft
SIRA 16 ATEX 5290X
Wagner International AG
Industriestrasse 22
CH - 9450 Altstätten
Made in Switzerland
Typ / Type:
EPG 5000
Artikel Nr.:
2359451
Article No.:
Serie Nr.:
Fan air
Control air
Serial No.:
Formluft
Baujahr:
Steuerluft
Year of manufacture:
Spannung:
115VAC - 230VAC
Voltage:
50Hz / 60Hz
Eingangsleistung:
max. 40W
Input Power:
Eingangsstrom:
max. 0.5A
Input Current:
Schutzart:
IP 40
IP Code:
Norm:
EN 50176:2009
Standard:
EN 50050-1:2013
Air input
6 - 8bar
87-116 psi
Clean and dry air
Saubere und trockene Luft
6.5.2 (ISO 8573-1:2010)
Restrictor for air during cleaning
Drossel für Luft während dem Spülen
B_05770
GA 5000EA
1
5
6
7
8
7 Grounding cable
8 Mains cable