Identification; Ce Explosion Protection Identification; Special Notice "X - WAGNER GA 5000EAIC Translation Of The Original Operating Manual

Electrostatic air spray gun
Table of Contents

Advertisement

VERSION 09/2016
OPERATING MANUAL
3

IDENTIFICATION

3.1

CE EXPLOSION PROTECTION IDENTIFICATION

As defi ned in the Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device type:
Manufacturer:
II 2 G 0.24mJ X
SIRA 16 ATEX5290X
SIRA 16 ATEX5290X Number of type examination certifi cate
3.2

SPECIAL NOTICE "X"

Temperature notes
- Maximum surface temperature: 85 °C; 185 °F
- Maximum permissible product temperature: 50 °C; 122 °F
- Permissible ambient temperature: 0 to +40 °C; +32 to +104 °F
Cable connections
Only cable assigned to the device may be used (see Chapter 13).
Permissible Device Combinations
The GA 5000EA automatic spray gun may only be connected to the control units listed below:
- EPG 5000 control unit
ORDER NUMBER DOC2360924
GA 5000EA electrostatic automatic spray gun
Wagner International AG
CH-9450 Altstätten, Switzerland
European Communities
Notifi ed body: PTB
Explosion-proof equipment
Device class II (not mining)
Category 2 device (suitable for zone 1)
Ex-atmosphere gas
Maximum ignition energy
X Special Notes (see Chapter 3.2)
GA 5000EA