OPERATING MANUAL
2.6

REASONABLY FORESEEABLE MISUSE

The forms of misuse listed below may result in physical injury or property damage:
use with non-authorized control units;
coating work pieces which are not grounded;
working with an ungrounded lacquer supply system;
performing unauthorized conversions or modifi cations to the device;
processing inadmissible coating products;
processing dry or similar coating products, e.g., powder;
using defective components, spare parts or accessories other than those described in
the "Accessories" chapter of this operating manual;
continuing work with a defective or kinked product hose;
working with incorrectly set values;
processing food.
2.7

RESIDUAL RISKS

Residual risks are risks which cannot be ruled out even in the event of correct use.
If necessary, warning and prohibition signs at the relevant points of risk indicate residual
risks.
Residual risk
Source
Skin contact with
Handling of
lacquers and
lacquers and
cleaning agents
cleaning agents
Lacquer in air
Lacquering outside
outside the defi ned
the defi ned working
working area
area
ORDER NUMBER DOC2360924
Consequences
Skin irritations,
allergies
Inhalation of
substances
hazardous to health
GA 5000EA
Specifi c measures
Wear protective
clothing
Observe safety data
sheets
Observe work and
operation instructions
Lifecycle phase
Operation,
maintenance,
disassembly
Operation,
maintenance