3
Commissioning
3.4.1
Bus node
FG S-0-1500.SI.0 (Bus Coupler)
Bus node CPX-FB39
Remote I/O operating mode
without diagnostics mode
2)
Status bits
I/O diagnostics interface
Remote Controller operating
4)
mode
1) Module identifier in the operator unit or in the hardware configuration of the programming software.
2) The additional input data are set up as FG S-0-1503.SI.0 (Digital Inputs).
3) Diagnostic mode status bits assigns 2 byte address space (8 inputs and/or 8 bits remain unused).
4) The additional input and output data are set up as FG S-0-1507.SI.0 (Complex Protocol).
5) Assigned address space depends upon the setting of DIL switch 2.2.
Tab. 3.1
If the bus node is operated in Remote Controller operating mode, then only the FG Bus
Coupler with additional FG Complex Protocol is depicted on structural entity 0. No depic
tion of I/O modules takes place on Sercos objects.
Festo – P.BE-CPX-FB39-EN – 1504NH – English
Module type
CPX-FB39
4)
CPX-FB39
Module
Allocated address space
1)
identifiers
Inputs
FB39-RIO
–
1x 16 bit
1x 16 bit
FB39-RC
8x 8bit
8x 16 bit
Outputs
–
3)
–
1x 16 bit
8x 8 bit
5)
5)
8x 16 bit
27