Installation
2.3

Mounting and dismantling

Warning
Electrical voltage
Injury caused by electric shock, damage to machine and to system
• Switch supply power off before assembly work.
2.3.1

Mounting

Please Note
Material damage due to incorrect mounting
• Select screws that are suitable for the material of the interlinking block:
– plastic: thread-cutting tapping screws
– metal: screws with metric thread.
When ordering an individual module, all the screws required are enclosed.
1. Check seal and sealing surface. Replace
damaged parts.
2. Push the module carefully and without tilting
into the interlinking block up to the stop.
3. Turn the screws into the existing thread.
4. Tighten the screws in diagonally opposite
sequence. Tightening torque: 0.9 ... 1.1 Nm.
1
Screws
2
Module
3
Interlinking block
Fig. 2.2
Please Note
In the Remote I/O operating mode, the bus node must be placed as the first module
(slot 0) to the far left of the CPX terminal.
2.3.2

Dismantling

1. Unscrew screws.
2. Pull the module without tilting out of the interlinking block.