Pressure Loss - RMG TME400-VMF Operating Manual

Turbine meter
Hide thumbs Also See for TME400-VMF:
Table of Contents

Advertisement

200
4000
300
200
4000
325
6500
400
325
6500
500
10000
500
500
10000
800
16000
600
800
16000
1250
25000

Pressure loss

1.4.2.10.
The measuring parts for determining pressure loss are 1 x DN upstream and down-
stream of the meter. The pressure loss is calculated according to the following formu-
la:
p
where:
Z
p
Q
m
DN nominal diameter
Device type
Turbine meter TME400
Perforated plate straightener L1 according to ISO/DIN
Perforated plate straightener L2 according to ISO/DIN
Perforated plate straightener L3 according to ISO/DIN
Perforated plate straightener LP-35 RMG standard
Bend straightener RB 19 according to ISO/DIN
The values for Z
are rough averages. The exact value is calculated from the pres-
p
sure loss, which is determined when testing the meter.
1:20
1:20
1:20
1:20
1:20
1:20
1:20
1:20
1:20
=
 
p
Z
p
pressure loss
coefficient of pressure loss
density
volume flow rate at measurement conditions [m³/h]
2
2
2
2
2
2
2
2
2
2
Q
m
4
DN
Manual TME400-VMF · EN02 · 2018 September 6th
1 Introduction
1
1
1
1
1
1
1
1
1
[mbar]
[-]
[kg/m³]
[mm]
Z
p
5040
3150
6300
9450
1260
1260
31